Effect of Outlet Pressure on Foam Performance in a Compressed Air Foam System
Fire · 10.03.2026 · 9 (3) · 120
DOI: 10.3390/fire9030120 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fire, online erschienen am 10.03.2026. Verfasst von Qing Ma und 5 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key R&D Program Projects in Hebei Province.
Abstract (Originalsprache)
This study investigates how outlet pressure influences the fire suppression performance of a compressed air foam system (CAFS), with the aim of supporting system optimization and engineering applications. An experimental apparatus for foam performance testing is used to measure changes in foam flow rate, expansion, initial velocity, initial momentum, and drainage time at different outlet pressures. On the basis of relevant theoretical models, the factors causing discrepancies between model predictions and experimental results are examined, and the models are then refined. How the outlet pressure of CAFS affects foam performance is thereby clarified. The results show that foam flow rate increases as outlet pressure increases. At higher pressures, shear-thinning and intensified gas–liquid mixing affect the foam. As a result, the growth of flow rate in the range of 0.01–0.03 MPa is significantly higher than that in the range of 0.06–0.10 MPa. Both initial velocity and initial momentum increase significantly with increasing pressure, whereas the expansion decreases. Within the outlet pressure range of 0.01–0.10 MPa, the initial velocity increases from 1.23 m/s to 6.65 m/s, the initial momentum rises from 4.6 kg·m/s to 34.1 kg·m/s, and the expansion decreases from 9.2 to 5.4, indicating reduced foam stability. Drainage time and drained mass vary non-monotonically with outlet pressure. The longest drainage time and the smallest drained mass occur at 0.06 MPa. Fire suppression performance improves as outlet pressure increases. A higher outlet pressure enables the foam solution to penetrate the flame zone more effectively and to cover the surface of the burning material. In addition, changes in foam properties enhance the thermal insulation and smothering effects of the foam layer, as well as its heat absorption and cooling capacity. These effects together improve the efficiency of fire source cooling.
Förderung
- Key R&D Program Projects in Hebei Province
Zitieren
APA
Ma, Q., Liu, C., Li, X., Li, D., Li, X., & Wu, Y. (2026). Effect of Outlet Pressure on Foam Performance in a Compressed Air Foam System. Fire, 9(3), 120. https://doi.org/10.3390/fire9030120
Vancouver
Ma Q, Liu C, Li X, Li D, Li X, Wu Y. Effect of Outlet Pressure on Foam Performance in a Compressed Air Foam System. Fire. 2026;9(3):120. doi:10.3390/fire9030120
BibTeX
@article{Ma2026,
author = {Ma, Qing and Liu, Chang and Li, Xiaobin and Li, Dawei and Li, Xinzhe and Wu, Yixuan},
title = {Effect of Outlet Pressure on Foam Performance in a Compressed Air Foam System},
journal = {Fire},
year = {2026},
volume = {9},
number = {3},
pages = {120},
doi = {10.3390/fire9030120}
}