EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ignition Delay and Reaction Time Measurements of Hydrogen–Air Mixtures at High Temperatures

Yauhen Baranyshyn, Vyacheslav Kuzmitski, Oleg Penyazkov, Kirill Sevrouk

Fire · 30.01.2024 · 7 (2) · 43

DOI: 10.3390/fire7020043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Fire, online erschienen am 30.01.2024. Verfasst von Yauhen Baranyshyn und 3 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: «Energy and nuclear processes and technologies 2.12» (2021–2025).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Induction and reaction times of hydrogen–air mixtures (ϕ = 0.5–2) have been measured behind reflected shock waves at temperatures of 1000–1600 K, pressures of 0.1, 0.3, 0.6 MPa in the domain of the extended second explosion limit. The measurements were performed in the shock tube with a completely transparent test section of 0.5 m long, which provides pressure, ion current, OH and high-speed chemiluminescence observations. The experimental induction time plots demonstrate a clear increasing of the global activation energy from high- to low temperature post-shock conditions. This trend is strongly pronounced at higher post-shock pressures. For a high-temperature range of T > 1200 K, induction time measurements show an activation energy for the global reaction rate of hydrogen oxidation of 64–83 kJ/mole. Detected reaction times exhibit a big scatter and a weak temperature dependence. The minimum reaction time value was nearly 2 µs. Obtained induction time data were compared with calculations carried out in accordance with the known kinetic mechanisms. For current and former shock-tube experiments within a pressure range of 0.1–2 MPa, critical temperatures required for strong (1000–1100 K), transient and weak auto-ignition modes behind reflected shock waves were identified by means of the pressure and ion-probe measurements in stoichiometric hydrogen-air mixture. The transfer from the strong volumetric self-ignition near the reflecting wall to the hot spot ignition (transient) was established and visualized below

Förderung

  • «Energy and nuclear processes and technologies 2.12» (2021–2025)

Zitieren

APA

Baranyshyn, Y., Kuzmitski, V., Penyazkov, O., & Sevrouk, K. (2024). Ignition Delay and Reaction Time Measurements of Hydrogen–Air Mixtures at High Temperatures. Fire, 7(2), 43. https://doi.org/10.3390/fire7020043

Vancouver

Baranyshyn Y, Kuzmitski V, Penyazkov O, Sevrouk K. Ignition Delay and Reaction Time Measurements of Hydrogen–Air Mixtures at High Temperatures. Fire. 2024;7(2):43. doi:10.3390/fire7020043

BibTeX
@article{Baranyshyn2024,
  author = {Baranyshyn, Yauhen and Kuzmitski, Vyacheslav and Penyazkov, Oleg and Sevrouk, Kirill},
  title = {Ignition Delay and Reaction Time Measurements of Hydrogen–Air Mixtures at High Temperatures},
  journal = {Fire},
  year = {2024},
  volume = {7},
  number = {2},
  pages = {43},
  doi = {10.3390/fire7020043}
}
Kostenlos starten →