Evaluation of Accuracy in Estimating Diameter at Breast Height Based on the Scanning Conditions of Terrestrial Laser Scanning and Circular Fitting Algorithm
Forests · 07.02.2024 · 15 (2) · 313
DOI: 10.3390/f15020313 ↗Kurz gefasst
Fachartikel in der Zeitschrift Forests, online erschienen am 07.02.2024. Verfasst von Yongkyu Lee und 1 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Forestry Service (Korea Forestry Promotion Institute).
Abstract (Originalsprache)
A growing societal interest exists in the application of lidar technology to monitor forest resource information and forestry management activities. This study examined the possibility of estimating the diameter at breast height (DBH) of two tree species, Pinus koraiensis (PK) and Larix kaempferi (LK), by varying the number of terrestrial laser scanning (TLS) scans (1, 3, 5, 7, and 9) and DBH estimation methods (circle fitting [CF], ellipse fitting [EF], circle fitting with RANSAC [RCF], and ellipse fitting with RANSAC [REF]). This study evaluates the combination that yields the highest estimation accuracy. The results showed that for PK, the lowest RMSE of 0.97 was achieved when REF was applied to the data from nine scans after noise removal. For LK, the lowest RMSE of 1.03 was observed when applying CF to the data from seven scans after noise removal. Furthermore, ANOVA revealed no significant difference in the estimated DBH from nine scans when more than three scans were used for CF and RCF and more than five for EF and REF. These results are expected to be useful in establishing efficient and accurate DBH estimation plans using TLS for forest resource monitoring.
Förderung
- Korea Forestry Service (Korea Forestry Promotion Institute)
Zitieren
APA
Lee, Y., & Lee, J. (2024). Evaluation of Accuracy in Estimating Diameter at Breast Height Based on the Scanning Conditions of Terrestrial Laser Scanning and Circular Fitting Algorithm. Forests, 15(2), 313. https://doi.org/10.3390/f15020313
Vancouver
Lee Y, Lee J. Evaluation of Accuracy in Estimating Diameter at Breast Height Based on the Scanning Conditions of Terrestrial Laser Scanning and Circular Fitting Algorithm. Forests. 2024;15(2):313. doi:10.3390/f15020313
BibTeX
@article{Lee2024,
author = {Lee, Yongkyu and Lee, Jungsoo},
title = {Evaluation of Accuracy in Estimating Diameter at Breast Height Based on the Scanning Conditions of Terrestrial Laser Scanning and Circular Fitting Algorithm},
journal = {Forests},
year = {2024},
volume = {15},
number = {2},
pages = {313},
doi = {10.3390/f15020313}
}