Abstract (Originalsprache)
Wood-burning fireplaces with inserts, wood-burning stoves, and pellet stoves are widely used as heating systems and as alternatives to fossil-fuel-based heating, although the particulate matter they emit can pose a significant risk to public health. A field campaign was conducted in France during the 2025–2026 winter season using several optical sensors (Pollutrack, LOAC2, and bcMeter) deployed in 44 individual houses to better characterize PM2.5 concentrations, particle size distributions, and the proportion of black carbon in emissions from these three heating systems. The measurement strategy relies on an original approach to estimating excess pollution, defined as the additional contribution of heating-related emissions to background ambient air pollution, using sensors strategically positioned both inside and around the houses. Emissions from fireplaces with inserts and wood-burning stoves can locally increase PM2.5 concentrations to several tens of µg.m−3. Pellet stoves exhibit the lowest PM2.5 mass concentrations, although particle number concentrations for particles between 0.15 and 1 µm are similar across the different heating systems. Pellet stoves may also contribute to local increases in secondary aerosol concentrations. On a daily average, these emissions contribute a few µg.m−3 to ambient PM2.5 concentrations. Finally, the ratio of PM2.5 mass concentration to black carbon mass concentration is approximately 10 indoors and does not appear to be a reliable indicator for distinguishing between the different heating systems. A measurement strategy is also proposed to improve the quantification of excess pollution attributable to residential heating.
Förderung
- European Climate Foundation, Clean Air Fund, La Poule Rousse
Zitieren
APA
Renard, J., Surcin, J., Renucci, T., Poincelet, E., Bourdrel, T., & Annesi-Maesano, I. (2026). Evaluation of PM2.5 Excess Pollution in Ambient Air from Different Wood Heating Systems, Using Optical Sensors in Individual Houses in France. Environments, 13(11), 625. https://doi.org/10.3390/environments13110625
Vancouver
Renard J, Surcin J, Renucci T, Poincelet E, Bourdrel T, Annesi-Maesano I. Evaluation of PM2.5 Excess Pollution in Ambient Air from Different Wood Heating Systems, Using Optical Sensors in Individual Houses in France. Environments. 2026;13(11):625. doi:10.3390/environments13110625
BibTeX
@article{Renard2026,
author = {Renard, Jean-Baptiste and Surcin, Jérémy and Renucci, Tony and Poincelet, Eric and Bourdrel, Thomas and Annesi-Maesano, Isabella},
title = {Evaluation of PM2.5 Excess Pollution in Ambient Air from Different Wood Heating Systems, Using Optical Sensors in Individual Houses in France},
journal = {Environments},
year = {2026},
volume = {13},
number = {11},
pages = {625},
doi = {10.3390/environments13110625}
}
EUVIMED