EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method

Iuliana Paun, Luoana Florentina Pascu, Vasile Ion Iancu, Florinela Pirvu, Toma Galaon, Florentina Laura Chiriac

Environments · 01.06.2024 · 11 (6) · 117

DOI: 10.3390/environments11060117 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environments, online erschienen am 01.06.2024. Verfasst von Iuliana Paun und 5 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Romanian Ministry of Research, Innovation, and Digitalization, National Research and Development Institute for Industrial Ecology—ECOIND.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A high-performance liquid chromatography with diode array detector (HPLC-DAD) analytical method was developed for the simultaneous detection of 17 phenolic compounds, including phenols, chlorophenols, alkylphenols, and nitrophenols, in two types of water matrices: wastewater and surface water. Prior to HPLC-DAD determination, a solid-phase extraction (SPE) procedure was optimized. The proposed method uses multiwavelength analysis, with the optimum detection wavelengths selected as 268 nm, 280 nm, 386 nm, 304 nm, and 316 nm. The highest resolution was achieved using a chromatographic column, Eclipse XDB-C18 (150 × 4.6 mm, 5 μm), which was kept at 20 °C. The mobile phase consisted of a gradient elution program, with mobile phase A being a 0.1% H3PO4 aqueous solution and mobile phase B being acetonitrile. The flow rate was set at 0.6 mL/min. The 17 target phenolic compounds were fully separated in less than 27 min. All compounds showed good linear regression, with correlation coefficients higher than 0.999. The method’s quantitation limits ranged from 4.38 to 89.7 ng/L for surface water and 7.83 to 167 ng/L for wastewater. The recovery rates were in the range of 86.2–95.1% for surface water and 79.1–86.3% for wastewater. The SPE-HPLC-DAD method was proven to be fast, sensitive, accurate, and reproducible. The developed method was successfully applied for the analysis of the 17 phenolic compounds in real surface water and wastewater samples, with phenol, 2,4-DNP, and 2,4-DNP being determined at levels greater than the method’s limits of quantitation (LOQs). The proposed analytical method represents an original technical resource for the simultaneous determination of 17 phenolic compounds in environmental water matrices.

Förderung

  • Romanian Ministry of Research, Innovation, and Digitalization
  • National Research and Development Institute for Industrial Ecology—ECOIND

Zitieren

APA

Paun, I., Pascu, L. F., Iancu, V. I., Pirvu, F., Galaon, T., & Chiriac, F. L. (2024). Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method. Environments, 11(6), 117. https://doi.org/10.3390/environments11060117

Vancouver

Paun I, Pascu LF, Iancu VI, Pirvu F, Galaon T, Chiriac FL. Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method. Environments. 2024;11(6):117. doi:10.3390/environments11060117

BibTeX
@article{Paun2024,
  author = {Paun, Iuliana and Pascu, Luoana Florentina and Iancu, Vasile Ion and Pirvu, Florinela and Galaon, Toma and Chiriac, Florentina Laura},
  title = {Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method},
  journal = {Environments},
  year = {2024},
  volume = {11},
  number = {6},
  pages = {117},
  doi = {10.3390/environments11060117}
}
Kostenlos starten →