EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression

Zainab Talib Al-Sharify, Firas M. Abdulsattar, Samer Ata Qasim Al-Ajooli, Ahmed Ali Farhan Ogaili, Alaa Abdulhady Jaber

Eng · 20.11.2026 · 7 (11) · 663

DOI: 10.3390/eng7110663 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eng, online erschienen am 20.11.2026. Verfasst von Zainab Talib Al-Sharify und 4 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early, non-invasive detection of the critical heat flux (CHF) is essential for the safe operation of nuclear, electronic-cooling and other high-heat-flux systems, yet conventional thermocouple-based monitoring is invasive, slow and point-wise. This paper presents an explainable deep-learning framework that classifies high-speed pool-boiling imagery into pre-CHF and post-CHF regimes and, in the same forward pass, regresses the energy-balance-derived equivalent vapour mass flux m″v. The proposed DL-Optimum model—a ResNet-50 backbone augmented with Squeeze-and-Excitation channel attention, label smoothing, cosine-annealed warm restarts and five-crop test-time augmentation—is benchmarked against six architectures on the open NED3 pool-boiling corpus of 3000 frames, and a stepwise ablation ladder (A0–A4) quantifies the cumulative contribution of each modification. DL-Optimum attains the highest performance (accuracy 0.9622, F1 0.9625, AUC-ROC 0.9772), reproduced under five-fold cross-validation (0.9622 ± 0.0058), confirmed on each of the five condition groups individually (0.939–0.983) and generalising to entirely unseen condition groups under leave-one-group-out cross-validation (0.8827 ± 0.0293). The regression head achieves an MAE of 0.041 kg·m−2·s−1 (R2 = 0.913) against the energy-balance ground truth. Grad-CAM attributions are consistent with physically relevant regions—nucleation-site activity and vapour-blanket morphology—Monte-Carlo Dropout yields calibrated confidence (predictive entropy 0.0674 ± 0.1024), and stress tests retain 0.902 accuracy from 10% of the training data and 0.938 at σ = 0.20 additive noise. An accuracy–efficiency analysis identifies DL-Optimum as accuracy-Pareto-optimal (26.30 M parameters; 332 FPS single-pass, ≈33 FPS under the full ten-pass test-time-augmentation protocol) and EfficientNet-B0 as efficiency-Pareto-optimal, and DL-Optimum achieves a 3.2 percentage-point higher in-distribution accuracy than the best published image-based CHF baseline (0.930) and a 1.2 percentage-point higher accuracy than the published acoustic baseline (0.950), though direct comparisons remain subject to cross-study differences in datasets and evaluation protocols.

Zitieren

APA

Al-Sharify, Z. T., Abdulsattar, F. M., Al-Ajooli, S. A. Q., Ogaili, A. A. F., & Jaber, A. A. (2026). Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression. Eng, 7(11), 663. https://doi.org/10.3390/eng7110663

Vancouver

Al-Sharify ZT, Abdulsattar FM, Al-Ajooli SAQ, Ogaili AAF, Jaber AA. Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression. Eng. 2026;7(11):663. doi:10.3390/eng7110663

BibTeX
@article{AlSharify2026,
  author = {Al-Sharify, Zainab Talib and Abdulsattar, Firas M. and Al-Ajooli, Samer Ata Qasim and Ogaili, Ahmed Ali Farhan and Jaber, Alaa Abdulhady},
  title = {Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression},
  journal = {Eng},
  year = {2026},
  volume = {7},
  number = {11},
  pages = {663},
  doi = {10.3390/eng7110663}
}
Kostenlos starten →