EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube

Jianyu Lin, Ponepen Laphirattanakul, Suvanjan Bhattacharyya, Piphatpong Thapmanee, Khwanchit Wongcharee, Pichit Kaewkosum, Suriya Chokphoemphun, Smith Eiamsa-ard

Eng · 11.03.2026 · 7 (3) · 128

DOI: 10.3390/eng7030128 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eng, online erschienen am 11.03.2026. Verfasst von Jianyu Lin und 7 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: School of Engineering, King Mongkut’s Institute of Technology Ladkrabang.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study experimentally investigates the thermal–hydraulic performance of heat exchanger tubes fitted with wired twisted tapes, with particular emphasis on the effects of the hole spacing-to-width ratio (s/W) and edge margin-to-width ratio (e/W). Experiments were conducted over a Reynolds number range of 6000–20,000, and the results were compared with those of plain tubes and tubes equipped with conventional twisted tapes. The findings revealed that the incorporation of wires significantly enhanced heat transfer due to the combined action of longitudinal eddies generated by wire protrusions and swirling flow induced by the twisted tape. At identical Reynolds numbers, tubes with a smaller hole spacing (s/W = 0.16) exhibited superior heat transfer performance, achieving Nusselt number enhancements of up to 107.7% relative to plain tubes and 51.6% relative to conventional twisted tapes. Similarly, reducing the edge margin ratio intensified near-wall eddies and further disrupted the boundary layer. The friction factor was found to increase with decreasing hole spacing and edge margin, primarily due to additional flow obstructions and enhanced near-wall shear stresses. For wired twisted tapes with s/W = 0.16, the friction factor reached nearly six times that of a plain tube. Despite this penalty, the thermal performance factor (TPF) remained favorable, with values of up to 1.2, indicating that the heat transfer benefits outweighed the corresponding pressure losses.

Förderung

  • School of Engineering, King Mongkut’s Institute of Technology Ladkrabang

Zitieren

APA

Lin, J., Laphirattanakul, P., Bhattacharyya, S., Thapmanee, P., Wongcharee, K., Kaewkosum, P., Chokphoemphun, S., & Eiamsa-ard, S. (2026). Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube. Eng, 7(3), 128. https://doi.org/10.3390/eng7030128

Vancouver

Lin J, Laphirattanakul P, Bhattacharyya S, Thapmanee P, Wongcharee K, Kaewkosum P, et al. Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube. Eng. 2026;7(3):128. doi:10.3390/eng7030128

BibTeX
@article{Lin2026,
  author = {Lin, Jianyu and Laphirattanakul, Ponepen and Bhattacharyya, Suvanjan and Thapmanee, Piphatpong and Wongcharee, Khwanchit and Kaewkosum, Pichit and Chokphoemphun, Suriya and Eiamsa-ard, Smith},
  title = {Influence of Wired Twisted Tape on Heat Transfer Enhancement, Friction Factor and Thermal Performance Behaviors in a Heat Exchanger Tube},
  journal = {Eng},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {128},
  doi = {10.3390/eng7030128}
}
Kostenlos starten →