EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Parametric Investigation of Climate-Responsive Roof Design Strategies for Buildings in India

Sudha Gopalakrishnan, Radhakrishnan Shanthi Priya, Yoo Kee Law, Chng Saun Fong, Ramalingam Senthil

Eng · 02.03.2026 · 7 (3) · 119

DOI: 10.3390/eng7030119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Eng, online erschienen am 02.03.2026. Verfasst von Sudha Gopalakrishnan und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid urbanization has significantly increased energy demand in buildings, which now represent nearly 30% of global energy use. In India, buildings are built across highly varied climatic conditions, from hot-dry and warm-humid to cold, high-altitude areas, making climate-responsive envelope design essential to enhance thermal performance. Among envelope components, roofs are the most exposed to solar and outdoor thermal loads, playing a key role in managing indoor heat transfer. This study offers a parametric analysis of climate-responsive roof design strategies for India’s five main climatic zones, using transient simulations and statistical evaluation. The effectiveness of insulation placement, insulation material and thickness, and external surface absorptivity was systematically assessed based on roof heat gain and heat loss. Results indicate that over-slab insulation can lower roof heat gain by approximately 15–35% compared to under-slab insulation in warm-humid, hot-dry, composite, and temperate zones. In comparison, under-slab insulation decreases heat loss by about 10% in colder areas. Among insulation materials, 50 mm polyurethane foam (U = 0.433 W/m2·K) consistently outperformed extruded polystyrene and expanded polystyrene, achieving 82–83% reductions in maximum heat gain in cooling-dominated climates and 89% reductions in heat loss in cold regions relative to uninsulated roofs. When combined with a white reflective surface finish (α = 0.26), the total heat transfer reduction increased further to 89–92%. Surface treatments alone cut heat gain by 37–51% in non-cold climates, highlighting their potential as cost-effective retrofit options. Statistical analysis confirmed that dry-bulb temperature is the primary climatic factor influencing roof heat transfer (R2 = 0.86–0.98, p < 0.0001), while solar radiation had a weaker effect, especially in optimized roof systems. The findings emphasize the importance of climate-specific roof design and demonstrate that insulation U-value has a greater impact on thermal performance than surface absorptivity, although both are significant. This research offers practical, climate-adjusted guidance for architects, engineers, and policymakers to enhance the thermal performance of roofs in Indian buildings. It supports the development of more resilient, energy-efficient building envelopes.

Zitieren

APA

Gopalakrishnan, S., Priya, R. S., Law, Y. K., Fong, C. S., & Senthil, R. (2026). Parametric Investigation of Climate-Responsive Roof Design Strategies for Buildings in India. Eng, 7(3), 119. https://doi.org/10.3390/eng7030119

Vancouver

Gopalakrishnan S, Priya RS, Law YK, Fong CS, Senthil R. Parametric Investigation of Climate-Responsive Roof Design Strategies for Buildings in India. Eng. 2026;7(3):119. doi:10.3390/eng7030119

BibTeX
@article{Gopalakrishnan2026,
  author = {Gopalakrishnan, Sudha and Priya, Radhakrishnan Shanthi and Law, Yoo Kee and Fong, Chng Saun and Senthil, Ramalingam},
  title = {Parametric Investigation of Climate-Responsive Roof Design Strategies for Buildings in India},
  journal = {Eng},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {119},
  doi = {10.3390/eng7030119}
}
Kostenlos starten →