Heat Transfer Analysis in a Channel Mounted with In-Line Downward-Facing and Staggered Downward-Facing Notched Baffles
Eng · 05.09.2025 · 6 (9) · 229
DOI: 10.3390/eng6090229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Eng, online erschienen am 05.09.2025. Verfasst von A. Phila und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: School of Engineering, King Mongkut’s Institute of Technology Ladkrabang.
Abstract (Originalsprache)
This study presents a comprehensive analysis of heat transfer enhancement, flow resistance, and thermal performance in rectangular channels equipped with three baffle configurations: conventional transverse baffles (TBs), in-line downward-facing notched baffles (IDF-NBs), and staggered downward-facing notched baffles (SDF-NBs). The influence of the pitch-to-baffle height ratio (P/e), ranging from 2.0 to 10, was examined across Reynolds numbers from 6000 to 24,000. Results indicate that a P/e ratio of 6.0 consistently yielded the highest Nusselt numbers across all configurations. While the TB configuration produced significant heat transfer at P/e= 6.0, it experienced a substantial friction penalty, with its best thermal enhancement factor (TEF = 1.168) observed at P/e = 8.0. The IDF-NB configuration achieved optimal performance at P/e = 6.0 with a TEF of 1.257, offering a better balance between heat transfer and flow resistance. The SDF-NB arrangement outperformed all other cases, delivering the highest Nusselt number (Nu = 116.9), TEF (1.362), and improved flow reattachment, primarily due to enhanced mixing from the staggered layout. These findings demonstrate that the staggered notched baffle configuration at P/e = 6.0 offers the most effective thermal performance enhancement among the configurations studied.
Förderung
- School of Engineering, King Mongkut’s Institute of Technology Ladkrabang
Zitieren
APA
Phila, A., Keaitnukul, W., Kumar, M., Pimsarn, M., Chokphoemphun, S., & Eiamsa-Ard, S. (2025). Heat Transfer Analysis in a Channel Mounted with In-Line Downward-Facing and Staggered Downward-Facing Notched Baffles. Eng, 6(9), 229. https://doi.org/10.3390/eng6090229
Vancouver
Phila A, Keaitnukul W, Kumar M, Pimsarn M, Chokphoemphun S, Eiamsa-Ard S. Heat Transfer Analysis in a Channel Mounted with In-Line Downward-Facing and Staggered Downward-Facing Notched Baffles. Eng. 2025;6(9):229. doi:10.3390/eng6090229
BibTeX
@article{Phila2025,
author = {Phila, A. and Keaitnukul, W. and Kumar, M. and Pimsarn, M. and Chokphoemphun, S. and Eiamsa-Ard, S.},
title = {Heat Transfer Analysis in a Channel Mounted with In-Line Downward-Facing and Staggered Downward-Facing Notched Baffles},
journal = {Eng},
year = {2025},
volume = {6},
number = {9},
pages = {229},
doi = {10.3390/eng6090229}
}
EUVIMED