EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Strategies for Pumped-Storage Hydropower to Participate in the Electric Energy and Ramp Rate Markets Considering Net Load Forecast Error

Xiaobi Teng, Kangping Qin, Bingbing Song, Hongyu He, Yutian Chen, Min Wen

Energies · 20.11.2026 · 19 (22) · 5619

DOI: 10.3390/en19225619 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 20.11.2026. Verfasst von Xiaobi Teng und 5 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the continuous expansion of grid-connected variable renewable energy such as wind power and photovoltaic power, sharp short-term fluctuations in system net load have intensified, posing challenges to conventional energy market dispatch in ramping resource allocation. However, existing ramping market clearing studies still lack an in-depth treatment of how large-capacity, long-duration storage resources such as pumped-storage hydropower participate in the ramping market, and they tend to oversimplify net-load forecast uncertainty. To address this, this paper proposes a joint clearing method for pumped-storage hydropower participating in both the electric energy and ramping markets while accounting for net-load forecast errors. First, a non-parametric kernel density estimation approach models the probability distribution of forecast errors, decomposing ramping demand into a forecast fluctuation component and an uncertainty margin component at a given confidence level. Second, a refined pumped-storage hydropower operational model is established considering state transition and upper reservoir constraints. On this basis, a joint electricity ramping clearing model is built integrating thermal units, pumped-storage hydropower, demand response, and renewable curtailment, aiming to minimise total operating cost. A case study on a Chinese provincial power grid shows that accounting for forecast errors raises the renewable integration rate from 91.4% to 93.2%, and pumped-storage hydropower participation further lifts it to 94.7% while cutting total operating cost by 5.552 million yuan.

Zitieren

APA

Teng, X., Qin, K., Song, B., He, H., Chen, Y., & Wen, M. (2026). Strategies for Pumped-Storage Hydropower to Participate in the Electric Energy and Ramp Rate Markets Considering Net Load Forecast Error. Energies, 19(22), 5619. https://doi.org/10.3390/en19225619

Vancouver

Teng X, Qin K, Song B, He H, Chen Y, Wen M. Strategies for Pumped-Storage Hydropower to Participate in the Electric Energy and Ramp Rate Markets Considering Net Load Forecast Error. Energies. 2026;19(22):5619. doi:10.3390/en19225619

BibTeX
@article{Teng2026,
  author = {Teng, Xiaobi and Qin, Kangping and Song, Bingbing and He, Hongyu and Chen, Yutian and Wen, Min},
  title = {Strategies for Pumped-Storage Hydropower to Participate in the Electric Energy and Ramp Rate Markets Considering Net Load Forecast Error},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5619},
  doi = {10.3390/en19225619}
}
Kostenlos starten →