Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers
Energies · 20.11.2026 · 19 (22) · 5618
DOI: 10.3390/en19225618 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 20.11.2026. Verfasst von Weixiang Huang und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of Guangxi Power Grid Co., Ltd..
Abstract (Originalsprache)
A single lightning strike on a double-circuit transmission line with shared towers may affect both circuits, while lightning risk varies among towers along the line. This study examines a 110 kV line in Guangxi, China, using lightning monitoring and operational records. Multi-wave-impedance models of representative tower types were developed in ATP-EMTP, and lightning withstand levels were determined using an insulator voltage–time characteristic criterion implemented in MODELS. An electrogeometric model was then used to estimate tower-level shielding-failure and backflashover trip-out rates, classify lightning risk, and propose a line surge arrester configuration. Thirty-three towers were identified for priority protection. In a model-based preliminary assessment, the estimated lightning-induced trip-out rate decreased from 9.747 to 2.579 trips per 100 km per year, a reduction of 73.54%. This case study provides a reference for differentiated lightning protection of similar lines.
Förderung
- Science and Technology Project of Guangxi Power Grid Co., Ltd.
Zitieren
APA
Huang, W., Xia, X., Yang, Y., Yi, C., Chen, X., & Huang, Z. (2026). Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers. Energies, 19(22), 5618. https://doi.org/10.3390/en19225618
Vancouver
Huang W, Xia X, Yang Y, Yi C, Chen X, Huang Z. Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers. Energies. 2026;19(22):5618. doi:10.3390/en19225618
BibTeX
@article{Huang2026,
author = {Huang, Weixiang and Xia, Xiaofei and Yang, Yixiong and Yi, Chenying and Chen, Xi and Huang, Zhidu},
title = {Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers},
journal = {Energies},
year = {2026},
volume = {19},
number = {22},
pages = {5618},
doi = {10.3390/en19225618}
}
EUVIMED