EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inlet-Temperature Disturbance Rejection in Solar Collector Fields Using Learning-Based Practical Nonlinear Predictive Control

Igor M. L. Pataro, Juan D. Gil, José L. Guzmán, Manuel Berenguel, Teodoro Alamo

Energies · 19.11.2026 · 19 (22) · 5607

DOI: 10.3390/en19225607 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 19.11.2026. Verfasst von Igor M. L. Pataro und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Innovation and Universities, Junta de Andalucia, Consejería de Universidad, Investigación e Innovación.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid variations in the Heat-Transfer-Fluid (HTF) inlet temperature can disrupt outlet-temperature regulation in solar collector fields, particularly when fast recovery interacts with delayed control action. This work assesses the previously developed Learning-Based Practical Nonlinear Model Predictive Controller (LBPNMPC) for rejecting such disturbances, motivated by expansion-vessel fluid-exchange transients observed at an actual facility. A matched clear-day simulation uses fourteen inlet-temperature disturbances generated from five experimentally measured profiles. LBPNMPC is compared with conventional filtered-error PNMPC, both with measured-disturbance feedforward, and with PNMPC without disturbance feedforward. In this matched simulation, LBPNMPC reduces the inlet-event integral absolute error by 34.3%, integral squared error by 49.3%, mean recovery time by 23.9%, and HTF-flow total variation by 11.4% relative to conventional filtered-error PNMPC. Experimental operation is assessed at the CIESOL research centre, University of Almería, Spain. During a severe 9.27 ∘C inlet-temperature decrease, the corresponding measured outlet-temperature decrease was 5.60 ∘C, approximately 60% of the inlet-temperature variation. The experiment demonstrates the practical applicability of LBPNMPC during a severe inlet-temperature disturbance, complementing the quantitative comparison with conventional PNMPC provided by the matched simulation.

Förderung

  • Ministry of Science, Innovation and Universities
  • Junta de Andalucia, Consejería de Universidad, Investigación e Innovación

Zitieren

APA

Pataro, I. M. L., Gil, J. D., Guzmán, J. L., Berenguel, M., & Alamo, T. (2026). Inlet-Temperature Disturbance Rejection in Solar Collector Fields Using Learning-Based Practical Nonlinear Predictive Control. Energies, 19(22), 5607. https://doi.org/10.3390/en19225607

Vancouver

Pataro IML, Gil JD, Guzmán JL, Berenguel M, Alamo T. Inlet-Temperature Disturbance Rejection in Solar Collector Fields Using Learning-Based Practical Nonlinear Predictive Control. Energies. 2026;19(22):5607. doi:10.3390/en19225607

BibTeX
@article{Pataro2026,
  author = {Pataro, Igor M. L. and Gil, Juan D. and Guzmán, José L. and Berenguel, Manuel and Alamo, Teodoro},
  title = {Inlet-Temperature Disturbance Rejection in Solar Collector Fields Using Learning-Based Practical Nonlinear Predictive Control},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5607},
  doi = {10.3390/en19225607}
}
Kostenlos starten →