EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads

Carlos Gustavo Castelo Branco, Jose Matas, Zhihao Min, Ganzhou Yao, Josep Maria Guerrero

Energies · 19.11.2026 · 19 (22) · 5606

DOI: 10.3390/en19225606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 19.11.2026. Verfasst von Carlos Gustavo Castelo Branco und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Spanish Ministerio de Ciencia, Innovación y Uni versidades (MICIU)—Agencia Estatal de Investigación.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions. Existing PQ calculation methods have been developed independently, most using a second-order generalized integrator (SOGI) approach, masking their structural relationships. This paper introduces a unified framework that interprets these PQ calculation approaches as combinations of input filters, intermediate notch filters, and output low-pass filters, enabling a clear spectral-domain analysis. Using this framework, the paper reveals that the current-side orthogonal filter in the fastest previously reported method (PQ4) causes a reactive power undershoot during load transients due to insufficient filtering. To overcome this limitation, a novel scheme (PQ2m) relocates the orthogonal filter to the voltage side and adds current-side SOGI filtering for improved distortion rejection. Analytical dynamic modeling enables a systematic design procedure, achieving an overshoot-free, dominant second-order response. Furthermore, incorporating notch filters (NFs) yields the PQ2mn variant and alternative PQ2mnb and PQ2mnc designs, which significantly suppress the output ripple while further accelerating the response speed. Hardware-in-the-Loop (HIL) results confirm settling-time reductions of up to 92.9% (PQ2m/PQ2mn), 95.75% (PQ2mnb), and 96.9% (PQ2mnc) compared to the conventional PQ1 method. Among all configurations, PQ2mn provides the best overall trade-off between dynamic enhancement and computational complexity.

Förderung

  • Spanish Ministerio de Ciencia, Innovación y Uni versidades (MICIU)—Agencia Estatal de Investigación

Zitieren

APA

Branco, C. G. C., Matas, J., Min, Z., Yao, G., & Guerrero, J. M. (2026). A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads. Energies, 19(22), 5606. https://doi.org/10.3390/en19225606

Vancouver

Branco CGC, Matas J, Min Z, Yao G, Guerrero JM. A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads. Energies. 2026;19(22):5606. doi:10.3390/en19225606

BibTeX
@article{Branco2026,
  author = {Branco, Carlos Gustavo Castelo and Matas, Jose and Min, Zhihao and Yao, Ganzhou and Guerrero, Josep Maria},
  title = {A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5606},
  doi = {10.3390/en19225606}
}
Kostenlos starten →