Real-Time Frequency Regulation of a Two-Area Power Plant with PV Grid and Thermal Generator Using an Adaptive Nonlinear Controller

Emre Çelik, Nihat Öztürk, Gulshan Sharma, Davut İzci, Cemil Ocak, Mahmoud Abdel-Salam

Energies · 19.11.2026 · 19 (22) · 5591

DOI: 10.3390/en19225591 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 19.11.2026. Verfasst von Emre Çelik und 5 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Düzce University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When the electricity generation does not meet the consumption, it causes undulations in area frequency and exchanging power in transmission lines. Frequency regulation (FR) is an inevitable mechanism for damping such undulations over the grid. In the work, an adaptive nonlinear PI (ANPI) controller is designed and its FR performance is evaluated on a two-area power plant consisting of photovoltaic (PV) system and thermal generator. In the controller presented, a sector-bounded nonlinear gain K based on a hyperbolic function is incorporated in cascade with a classical PI controller. To increase the degree of freedom during the design stage, the hyperbolic function is shaped by the two parameters. Stochastic fractal search (SFS) algorithm via the minimization of ITAE criterion is adopted to identify the best combination of controller parameters in attempting to acquire the maximum possible benefit from the controller. The ANPI controller is contrasted against similar works in the arena. It is found that using the ANPI controller the ITAE criterion is lowered to 2.291 from its known best value of 2.343, yielding an improvement of 2.25%. In line with this reduction, larger improvements up to 44.6% in settling time and frequency/tie-line deviations are obtained by employing the proposed approach. As a result, undulations in frequency and tie-line power responses are suppressed, and the responses are able to achieve the steady state value of zero more shortly. After carrying out the analysis of robustness to parameter uncertainty, measurement noise and renewable generation intermittence, the ANPI controller appears to perform robustly. The proposed method is affirmed through using the OPAL-RT OP4605XG2 real-time simulator.

Förderung

  • Düzce University

Zitieren

APA

Çelik, E., Öztürk, N., Sharma, G., İzci, D., Ocak, C., & Abdel-Salam, M. (2026). Real-Time Frequency Regulation of a Two-Area Power Plant with PV Grid and Thermal Generator Using an Adaptive Nonlinear Controller. Energies, 19(22), 5591. https://doi.org/10.3390/en19225591

Vancouver

Çelik E, Öztürk N, Sharma G, İzci D, Ocak C, Abdel-Salam M. Real-Time Frequency Regulation of a Two-Area Power Plant with PV Grid and Thermal Generator Using an Adaptive Nonlinear Controller. Energies. 2026;19(22):5591. doi:10.3390/en19225591

BibTeX
@article{elik2026,
  author = {Çelik, Emre and Öztürk, Nihat and Sharma, Gulshan and İzci, Davut and Ocak, Cemil and Abdel-Salam, Mahmoud},
  title = {Real-Time Frequency Regulation of a Two-Area Power Plant with PV Grid and Thermal Generator Using an Adaptive Nonlinear Controller},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5591},
  doi = {10.3390/en19225591}
}
Kostenlos starten →