Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids
Energies · 18.11.2026 · 19 (22) · 5580
DOI: 10.3390/en19225580 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 18.11.2026. Verfasst von Naresh Kumar Vemula und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Inverter technology has emerged as a key enabler for renewable energy integration and power delivery in modern microgrids (MGs). Digital time delays associated with measurement, computation, and pulse-width modulation can significantly affect the dynamic performance and stability of islanded inverter-fed microgrids. This paper presents an internal model control (IMC)-based current controller with explicit digital time-delay compensation to improve stability and dynamic performance by addressing delay-induced oscillatory interactions among different control layers. A comprehensive small-signal model is developed by incorporating power, voltage, and current control loops, digital time delay, LC filter, network, and load dynamics. The third-order Padé model of the delay is verified against the exact delay, and system stability is evaluated through eigenvalues, damping ratios and participation factors. At the nominal delay of 15 μs (1.5Ts, Ts=10μs), the current-loop modes of the IMC without compensation are almost undamped (ζ≈0.002) and become unstable beyond 15.25 μs, whereas the proposed controller damps the same modes with ζ=0.29 and remains stable up to 24.75 μs. The proposed design is also compared with a Smith predictor, its robustness to filter, line and load variations is assessed, and particle swarm optimization (PSO) with an explicit stability constraint raises the minimum damping ratio to 0.62. The effectiveness of the proposed approach is verified through comparison with a conventional IMC controller without delay compensation using the OPAL-RT OP4510 real-time simulator, where it reduces the frequency overshoot after load changes from about 30% to below 4% of the steady-state deviation.
Zitieren
APA
Vemula, N. K., Hasan, M. A., Irshad, M., Mishra, P., & Verma, A. K. (2026). Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids. Energies, 19(22), 5580. https://doi.org/10.3390/en19225580
Vancouver
Vemula NK, Hasan MA, Irshad M, Mishra P, Verma AK. Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids. Energies. 2026;19(22):5580. doi:10.3390/en19225580
BibTeX
@article{Vemula2026,
author = {Vemula, Naresh Kumar and Hasan, Muhammad Asif and Irshad, Mohammad and Mishra, Pratikanta and Verma, Alok Kumar},
title = {Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids},
journal = {Energies},
year = {2026},
volume = {19},
number = {22},
pages = {5580},
doi = {10.3390/en19225580}
}
EUVIMED