EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids

Zifan Zhang, Panmei Zhang, Hanlin Yu, Zhanhong Liang, Zhidong Wang

Energies · 18.11.2026 · 19 (22) · 5569

DOI: 10.3390/en19225569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 18.11.2026. Verfasst von Zifan Zhang und 4 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangzhou City University of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Converter current and power limits alter the fault voltage–current relationship in microgrids. This paper coordinates a bounded voltage-dependent pickup characteristic with mode-specific setting groups for passive laterals and their immediate backups. A common balanced static source model is used for pre-fault, fault, and post-clearance calculations. An outer differential-evolution search determines pickup parameters, monotone propagation solves the fixed-pickup timing inequalities, and an independent linear program checks selected timing solutions. The 10 kV, 14-bus study includes 450 setting faults and 210 validation faults, with 280 prescribed validation events. Under the same two-group configuration and a 40 ms trip-command floor, voltage supervision with separate joint retuning reduces islanded target-pair TROT by 30.11% over 30 bus-14 faults and by 10.30% over all 70 bus-14 target faults relative to IDMT. The mean main-protection trip-command delay over all 210 validation faults decreases from 49.743 to 48.584 ms (2.33%). All prescribed validation events pass the proposed-setting checks, with a minimum worst-case CTI of 300.078 ms and a minimum error-adjusted normal pickup margin of 1.25101. Nine design-parameter combinations use twenty seeds per group and the same selection rule as the principal benchmark. The grouping provides mode-specific setting management; no incremental clustering benefit or quantified single-to-two-group improvement is established. Conclusions apply to the finite balanced static libraries, fixed source ratings and internal topology, and correct pre-fault group selection.

Förderung

  • Guangzhou City University of Technology

Zitieren

APA

Zhang, Z., Zhang, P., Yu, H., Liang, Z., & Wang, Z. (2026). Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids. Energies, 19(22), 5569. https://doi.org/10.3390/en19225569

Vancouver

Zhang Z, Zhang P, Yu H, Liang Z, Wang Z. Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids. Energies. 2026;19(22):5569. doi:10.3390/en19225569

BibTeX
@article{Zhang2026,
  author = {Zhang, Zifan and Zhang, Panmei and Yu, Hanlin and Liang, Zhanhong and Wang, Zhidong},
  title = {Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5569},
  doi = {10.3390/en19225569}
}
Kostenlos starten →