EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Conceptual Data Fusion Framework for Oscillation Risk Assessment in Renewable Power Systems

Yajun Zhang, Yuyao Feng, Xingang Yang, Aiqiang Pan

Energies · 18.11.2026 · 19 (22) · 5566

DOI: 10.3390/en19225566 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 18.11.2026. Verfasst von Yajun Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Corporation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oscillation assessment in renewable power systems must distinguish measurement confidence, source evidence, present condition, and future warning. This paper proposes a conceptual data fusion framework whose methodological contribution is an explicit set of dependency and evidence constraints: prediction is excluded from its current-risk target, propagation coefficients require valid physical connections, and unavailable observations remain distinguishable from zero risk. These constraints make assessment assumptions testable without claiming a new physical source locator. The numerical illustration audits a simplified 500 MVA offshore wind and HVDC benchmark with prescribed disturbances, power-deviation proxies, heuristic state scores, and a dependent four-level hierarchy. It does not implement signed branch-energy attribution, calibrated multiband filtering, estimated Markov transitions, or independent physical device-graph propagation. Equation replay reproduces the archived S01 and S12 outputs within floating-point precision. The imposed 25 Hz WF1 case reaches an internal source score of 0.963 and a legacy system score of 0.563. Controlled changes separate forcing reduction, power reduction, and the receiving-grid term. A 1 s restoration ramp lowers the combined-case full-record maximum from 0.567 to 0.341; removing only the WF1 forcing lowers the late-window legacy score to 0.0630 while residual grid effects persist. A prediction-free retrospective target exposes false-warning and missed-warning tradeoffs; the historical 0.861 s crossing separation is not predictive validation. Executable algebraic checks and a self-contained numerical supplement support verification of the stated scope. Independent physical and statistical validation remains necessary.

Förderung

  • State Grid Corporation of China

Zitieren

APA

Zhang, Y., Feng, Y., Yang, X., & Pan, A. (2026). A Conceptual Data Fusion Framework for Oscillation Risk Assessment in Renewable Power Systems. Energies, 19(22), 5566. https://doi.org/10.3390/en19225566

Vancouver

Zhang Y, Feng Y, Yang X, Pan A. A Conceptual Data Fusion Framework for Oscillation Risk Assessment in Renewable Power Systems. Energies. 2026;19(22):5566. doi:10.3390/en19225566

BibTeX
@article{Zhang2026,
  author = {Zhang, Yajun and Feng, Yuyao and Yang, Xingang and Pan, Aiqiang},
  title = {A Conceptual Data Fusion Framework for Oscillation Risk Assessment in Renewable Power Systems},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5566},
  doi = {10.3390/en19225566}
}
Kostenlos starten →