Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 16.11.2026. Verfasst von Xiaowei Feng und 4 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Inner Mongolia East Electric Power Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing penetration of photovoltaic (PV) generation introduces substantial uncertainties into microgrid energy management due to deviations between forecasted and actual generation and load demand. Conventional single-time-scale scheduling may impose additional regulation demands on batteries, increasing energy throughput, power fluctuations, and associated degradation costs. To address these challenges, this paper proposes a forecast-error-aware dual-time-scale hierarchical energy management strategy for a grid-connected PV microgrid equipped with a battery–supercapacitor hybrid energy storage system. The upper layer performs hourly economic scheduling by considering grid electricity transactions and battery degradation costs, while the lower layer conducts corrective optimization at 5 min intervals using updated source-load forecasts. Through receding-horizon optimization, reference tracking, and battery power-variation regulation, corrective power is coordinated among the battery, supercapacitor, and utility grid while respecting their operating constraints. A 48 h benchmark with three comparative strategies is conducted under a 10% normalized root mean square error (NRMSE), with all cases terminating at 10% battery SOC. Compared with conventional battery-based hourly scheduling, the proposed strategy reduces the total operating cost, battery energy throughput, and the battery power fluctuation index by 4.34%, 16.69%, and 38.40%, respectively. An additional 96 h evaluation, with battery SOC restored to 50% at successive period boundaries, retains a 9.96% reduction in the power fluctuation index but yields a higher operating cost and battery throughput. Sensitivity analysis under 5–20% NRMSE further shows relatively stable battery power fluctuations and increased supercapacitor utilization with forecasting uncertainty. These findings demonstrate the potential benefits of forecast-aware hierarchical coordination while indicating that economic and battery utilization outcomes depend on the operating scenario, evaluation horizon, and terminal-energy policy.

Förderung

  • State Grid Inner Mongolia East Electric Power Co., Ltd.

Zitieren

APA

Feng, X., Li, H., Liang, W., Zhou, W., & Zhang, W. (2026). Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage. Energies, 19(22), 5516. https://doi.org/10.3390/en19225516

Vancouver

Feng X, Li H, Liang W, Zhou W, Zhang W. Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage. Energies. 2026;19(22):5516. doi:10.3390/en19225516

BibTeX
@article{Feng2026,
  author = {Feng, Xiaowei and Li, He and Liang, Wei and Zhou, Wei and Zhang, Weiqi},
  title = {Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5516},
  doi = {10.3390/en19225516}
}
Kostenlos starten →