EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Counterfactual Probabilistic Electricity Load Baseline Estimation for Demand Response Using Contemporaneous Non-Activated Customers

Liang Shen, Yukun Bao

Energies · 12.11.2026 · 19 (22) · 5442

DOI: 10.3390/en19225442 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 12.11.2026. Verfasst von Liang Shen und 1 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measuring electricity demand response requires the electricity load that an activated customer would have exhibited without activation. Selective activation and shared disturbances complicate estimation of this unobserved baseline. This study develops Quantile Generalized Synthetic Control (QGSC), combining a historical conditional quantile predictor with residual information from contemporaneous non-activated customers. A shrinkage-controlled common location shift updates the predicted quantiles, followed by empirical interval calibration using held-out historical event controls. Evaluation combines measured commercial and industrial electricity load with simulated activation and response. Five overlapping 60-customer cohorts are drawn from a single-city pool of 102 customers. Relative to a CalTRACK-style regression, QGSC reduces the 19-quantile grid approximation to the continuous ranked probability score from 170.440 to 164.458 kW, or 3.51%. Nominal 90% interval coverage increases from 77.89% to 85.16%, accompanied by a 9.79% increase in normalized width. Point-measurement mean absolute error decreases by 3.33%. Matched ablations attribute most of the grid-score reduction to contemporaneous correction, while donor and subgroup diagnostics reveal residual bias and undercoverage. These descriptive results support a modest incremental benefit for ex-post measurement under the specified retrospective conditions. They do not establish nominal coverage, statistically significant main-experiment superiority, or performance under actual demand response operations.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Shen, L., & Bao, Y. (2026). Counterfactual Probabilistic Electricity Load Baseline Estimation for Demand Response Using Contemporaneous Non-Activated Customers. Energies, 19(22), 5442. https://doi.org/10.3390/en19225442

Vancouver

Shen L, Bao Y. Counterfactual Probabilistic Electricity Load Baseline Estimation for Demand Response Using Contemporaneous Non-Activated Customers. Energies. 2026;19(22):5442. doi:10.3390/en19225442

BibTeX
@article{Shen2026,
  author = {Shen, Liang and Bao, Yukun},
  title = {Counterfactual Probabilistic Electricity Load Baseline Estimation for Demand Response Using Contemporaneous Non-Activated Customers},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5442},
  doi = {10.3390/en19225442}
}