EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador

Marco Vivero Tenorio, René Cortijo Leyva, Henry Díaz-Iza

Energies · 12.11.2026 · 19 (22) · 5439

DOI: 10.3390/en19225439 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 12.11.2026. Verfasst von Marco Vivero Tenorio und 2 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Tecnológica Israel.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The electricity supply in rural communities of Ecuador faces limitations due to the strong dependence on hydropower sources and the lack of alternative backup systems. Photovoltaic systems with automated solar tracking mechanisms emerge as a viable alternative to optimize energy harvesting and enhance energy security. This study aims to design, implement, and validate a 200 Wp photovoltaic generator equipped with a 2000 W inverter with 100 Ah battery backup, integrating a two-axis automated solar tracking mechanism and a remote control interface accessible through mobile devices. The methodology included system sizing using the Photovoltaic Geographical Information System (PVGIS), structural modeling in Autodesk Inventor Professional, implementation of a control system based on an Arduino Mega 2560 with current, voltage, and temperature sensors, and the development of a remote monitoring interface using the RemoteXY platform. Experimental results showed that the tracking mechanism maintained the perpendicular orientation of the solar panels relative to incident radiation, achieving ranges of 137° in elevation and 47° in declination. Automatic switching through the ATS device was successfully verified without observable interruptions of the connected load. According to the manufacturer specifications, the ATS transfer time is below 50 ms, although this value was not independently measured during the experimental validation. Stable access to the remote interface was also achieved, with an external network connection success rate of 93.33%. The failure rate under low-radiation conditions was approximately 17%. The system represents a significant technological contribution for rural areas with limited access to reliable electricity, and establishes the basis for future improvements in control algorithms and sensor sensitivity for solar tracking systems.

Förderung

  • Universidad Tecnológica Israel

Zitieren

APA

Tenorio, M. V., Leyva, R. C., & Díaz-Iza, H. (2026). Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador. Energies, 19(22), 5439. https://doi.org/10.3390/en19225439

Vancouver

Tenorio MV, Leyva RC, Díaz-Iza H. Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador. Energies. 2026;19(22):5439. doi:10.3390/en19225439

BibTeX
@article{Tenorio2026,
  author = {Tenorio, Marco Vivero and Leyva, René Cortijo and Díaz-Iza, Henry},
  title = {Design and Experimental Validation of a Photovoltaic Backup System with Dual-Axis Solar Tracking and Remote Monitoring: A Case Study of Tabiazo, Ecuador},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5439},
  doi = {10.3390/en19225439}
}
Kostenlos starten →