EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Field Evaluation of a Photovoltaic–Wind Turbine–Battery DC Microgrid with a Concentrated Solar Thermoelectric Branch

Ovis D. Irefu, Godslove I. Ebiega, Breana G. Smithers, Miguel F. Acevedo

Energies · 12.11.2026 · 19 (22) · 5432

DOI: 10.3390/en19225432 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 12.11.2026. Verfasst von Ovis D. Irefu und 3 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation (NSF) Innovations at the Nexus of Food, Energy and Water Systems (INFEWS) program, U.S. Department of Agriculture (USDA) National Institute of Food and Agriculture, NSF Cyber-Physical Systems (CPS) program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microgrids that combine renewable generation with battery storage are being deployed in power systems worldwide to improve supply continuity and to integrate variable renewable energy, yet most evidence on their reliability comes from simulation, and field studies rarely report measured reliability indices together with the load, storage, and weather period under which they were obtained. This paper reports on the design and field evaluation of a 24 V direct-current microgrid at the University of North Texas Discovery Park, Denton, Texas, USA (33.2° N) that combines photovoltaic (PV) and wind generation with lead-acid storage and a parabolic-dish thermoelectric branch on a shared bus. Reliability was assessed from a 33-day metered campaign (696,595 records) and a design-basis suite using loss of power supply probability (LPSP), loss of load expectation (LOLE), expected energy not supplied (EENS), and two storage-independent indices. At the metered load, wind reduced battery-supplied energy by 17.9% (13.5% at night) and generation-adequacy LPSP from 47.9% to 39.4% by generating at night and under low irradiance. Under a 140 W design-basis load, wind reduced LPSP from 4.18% to 0.93% (EENS from 0.140 to 0.031 kWh/day), but the same load evaluated on the record, which covers a different period of measured weather, yielded up to 24.1%, showing that reliability indices depend jointly on load, storage, and the weather period over which they are computed. For the thermoelectric branch, characterized in seven campaigns over 32 days (19 August–19 September 2026), diagnostic elimination showed that manual-tracking dwell time and optical-interface coupling govern output; moving the thermoelectric module bank closer to the dish focal point, with the dish aiming procedure unchanged, raised delivered power from 13.11 W to 50.96 W.

Förderung

  • National Science Foundation (NSF) Innovations at the Nexus of Food, Energy and Water Systems (INFEWS) program
  • U.S. Department of Agriculture (USDA) National Institute of Food and Agriculture
  • NSF Cyber-Physical Systems (CPS) program

Zitieren

APA

Irefu, O. D., Ebiega, G. I., Smithers, B. G., & Acevedo, M. F. (2026). Field Evaluation of a Photovoltaic–Wind Turbine–Battery DC Microgrid with a Concentrated Solar Thermoelectric Branch. Energies, 19(22), 5432. https://doi.org/10.3390/en19225432

Vancouver

Irefu OD, Ebiega GI, Smithers BG, Acevedo MF. Field Evaluation of a Photovoltaic–Wind Turbine–Battery DC Microgrid with a Concentrated Solar Thermoelectric Branch. Energies. 2026;19(22):5432. doi:10.3390/en19225432

BibTeX
@article{Irefu2026,
  author = {Irefu, Ovis D. and Ebiega, Godslove I. and Smithers, Breana G. and Acevedo, Miguel F.},
  title = {Field Evaluation of a Photovoltaic–Wind Turbine–Battery DC Microgrid with a Concentrated Solar Thermoelectric Branch},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5432},
  doi = {10.3390/en19225432}
}
Kostenlos starten →