A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide

Mouna Nassim, Mohamed Bezza

Energies · 11.11.2026 · 19 (22) · 5417

DOI: 10.3390/en19225417 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 11.11.2026. Verfasst von Mouna Nassim und 1 weiteren Autor:innen. Die Arbeit nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data centers consume vast amounts of electricity, and cooling still accounts for a large share of it. Artificial intelligence is increasingly used to reduce this demand, but computing resources and cooling are usually optimized as two separate problems, a separation we call the IT–cooling divide. This review examines how AI is applied to cooling, to Information and Communication Technology (ICT) resources, and to the data center as a whole (Full-DC). We searched Scopus and Web of Science (last searched on 3 August 2026) for journal articles published in 2021–2025 that report quantitative results. We supplemented the database search with a targeted search of ScienceDirect and reference checking. We report the process following PRISMA 2020. As no formal risk-of-bias tool exists for simulation-based engineering studies, the validation level and baseline of each study were recorded, and results were synthesized narratively. The first author selected 45 studies (16 cooling, 21 ICT, 8 Full-DC) on the basis of titles and abstracts and read all of them in full for data extraction. Because selection was made by a single reviewer, the reported shares describe the reviewed sample rather than the whole literature; a reproducible re-screening of all 933 database records, checked double-blind by both authors, indicates that reinforcement learning is over-represented, and metaheuristics under-represented, in this sample. Reinforcement learning is the most frequent primary approach for control and deep learning for prediction. Energy results are heterogeneous: they use different baselines (PID control, heuristics, competing algorithms), are reported at different levels (cooling plant, IT servers, network, or facility), and come almost entirely from simulation, trace-driven, or offline evaluations; no included study reports closed-loop deployment in production. Among the studies reporting an energy reduction in percent, the median value is about 9% for cooling (n = 7) and 13% for ICT (n = 7), and the two Full-DC studies report 16–17%. Only two included studies explicitly co-optimize computing and cooling decisions. Joint IT–cooling optimization therefore remains a promising but thinly tested direction, and progress depends on facility-level reporting, real-world validation, and open datasets. The review was not registered and received no external funding.

Zitieren

APA

Nassim, M., & Bezza, M. (2026). A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide. Energies, 19(22), 5417. https://doi.org/10.3390/en19225417

Vancouver

Nassim M, Bezza M. A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide. Energies. 2026;19(22):5417. doi:10.3390/en19225417

BibTeX
@article{Nassim2026,
  author = {Nassim, Mouna and Bezza, Mohamed},
  title = {A Review of Artificial Intelligence for Data Center Energy Efficiency: Toward Bridging the IT–Cooling Divide},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {22},
  pages = {5417},
  doi = {10.3390/en19225417}
}
Kostenlos starten →