Stabilizing an AC-DC Micro-Grid Powered by Residual-Pressure Energy with the Additional Damping Controller of the Converter
Energies · 10.11.2026 · 19 (22) · 5400
DOI: 10.3390/en19225400 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 10.11.2026. Verfasst von Jun Xiang und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of State Grid Sichuan Electric Power Company.
Abstract (Originalsprache)
To address low-frequency oscillations in islanded residual-pressure power generation systems caused by water-hammer dynamics and low inertia, this paper proposes a supplementary damping control strategy for the DC-voltage outer loop of a voltage-source converter (VSC), using generator-speed deviation as feedback. First, an electromechanical control model is established, and its oscillatory characteristics are examined using root-locus and frequency-domain analyses. Then, with the supplementary controller disabled, a small-step signal is applied in PSCAD. TLS-ESPRIT is used to identify an equivalent second-order model between the supplementary control signal and generator electromagnetic power, and an independent small-step record is used for validation. Damping-torque theory is subsequently employed to determine the required phase compensation. A constrained particle swarm search is used to audit controller settings against frequency- and DC-voltage-related criteria, while nonlinear verification determines whether the candidate parameters should be adopted. The implemented controller comprises a low-pass filter, a washout stage, and a single-stage lead–lag network. In a unified three-level load check, the controller maintains stable operation for the added loads of 80 and 160 kW, whereas the 240 kW case went out of the normal operating range. In a separate reduced-order hydraulic-lag sensitivity test at 160 kW, the controller maintains bounded responses when Th2 is varied from 0.36 to 0.54 s. A matched benchmark against a conventional uncompensated supplementary branch shows that the proposed phase-compensated controller reduces frequency ITAE by 18.9% and limiter residence by 22.4% relative to the selected conventional case, although its DC-voltage ITAE is 67.4% higher. The results therefore support a frequency-recovery benefit within the tested range rather than a universal performance superiority.
Förderung
- Science and Technology Project of State Grid Sichuan Electric Power Company
Zitieren
APA
Xiang, J., Gou, J., Li, W., Xu, W., Li, A., & Liu, C. (2026). Stabilizing an AC-DC Micro-Grid Powered by Residual-Pressure Energy with the Additional Damping Controller of the Converter. Energies, 19(22), 5400. https://doi.org/10.3390/en19225400
Vancouver
Xiang J, Gou J, Li W, Xu W, Li A, Liu C. Stabilizing an AC-DC Micro-Grid Powered by Residual-Pressure Energy with the Additional Damping Controller of the Converter. Energies. 2026;19(22):5400. doi:10.3390/en19225400
BibTeX
@article{Xiang2026,
author = {Xiang, Jun and Gou, Jiabo and Li, Wei and Xu, Weiting and Li, Ao and Liu, Chang},
title = {Stabilizing an AC-DC Micro-Grid Powered by Residual-Pressure Energy with the Additional Damping Controller of the Converter},
journal = {Energies},
year = {2026},
volume = {19},
number = {22},
pages = {5400},
doi = {10.3390/en19225400}
}
EUVIMED