EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Robust Sensorless Nonlinear MPC for PMSG-Based Wind Energy Conversion Systems with Three-Level NPC Converters

Abdelmoghit Fathelkhair, Hassan Abouobaida, Mohamed Nabil Srifi, Ahmed S. Alsafran, Abdullah A. Algethami, Habib Kraiem, Safeer Ullah, Khalid Faitah, Younes Abouelmahjoub

Energies · 09.11.2026 · 19 (21) · 5378

DOI: 10.3390/en19215378 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 09.11.2026. Verfasst von Abdelmoghit Fathelkhair und 8 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Faisal University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes a computationally efficient sensorless control framework for a permanent magnet synchronous generator (PMSG)-based wind energy conversion system (WECS) employing three-level neutral-point-clamped (3L-NPC) back-to-back converters. A high-gain observer is developed to estimate grid voltages, frequency, and electrical angle, with its estimation error analyzed using Lyapunov theory to establish uniform ultimate boundedness. An integral sliding mode control (ISMC) combined with finite-control-set model-predictive control (FCS-MPC) is employed to regulate the system. To reduce the computational burden, a two-stage search algorithm is proposed, reducing the number of evaluated switching combinations from 27 to 7 per sampling period while maintaining comparable control performance. The proposed strategy is evaluated through Processor-in-the-Loop (PIL) simulations using MATLAB/Simulink and the LAUNCHXL-F28379D DSP platform. The observer is tested under sudden variations in grid voltage amplitude, abrupt frequency changes, frequency ramps, and measurement noise. The results show that the estimated variables converge toward their actual values, with increased fluctuations under measurement noise. The control strategy is evaluated under wind-speed variations and parametric uncertainties with a stochastic wind profile. Under nominal conditions, both FCS-MPC methods show comparable control performance, while the proposed method requires less execution time. Under parametric uncertainties, the proposed method improves DC-link voltage regulation and neutral-point voltage balancing, achieving a grid-current THD of 0.99%, compared with 2.43% for conventional FCS-MPC.

Förderung

  • King Faisal University

Zitieren

APA

Fathelkhair, A., Abouobaida, H., Srifi, M. N., Alsafran, A. S., Algethami, A. A., Kraiem, H., Ullah, S., Faitah, K., & Abouelmahjoub, Y. (2026). Robust Sensorless Nonlinear MPC for PMSG-Based Wind Energy Conversion Systems with Three-Level NPC Converters. Energies, 19(21), 5378. https://doi.org/10.3390/en19215378

Vancouver

Fathelkhair A, Abouobaida H, Srifi MN, Alsafran AS, Algethami AA, Kraiem H, et al. Robust Sensorless Nonlinear MPC for PMSG-Based Wind Energy Conversion Systems with Three-Level NPC Converters. Energies. 2026;19(21):5378. doi:10.3390/en19215378

BibTeX
@article{Fathelkhair2026,
  author = {Fathelkhair, Abdelmoghit and Abouobaida, Hassan and Srifi, Mohamed Nabil and Alsafran, Ahmed S. and Algethami, Abdullah A. and Kraiem, Habib and Ullah, Safeer and Faitah, Khalid and Abouelmahjoub, Younes},
  title = {Robust Sensorless Nonlinear MPC for PMSG-Based Wind Energy Conversion Systems with Three-Level NPC Converters},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {5378},
  doi = {10.3390/en19215378}
}