Heat-to-Power Matching Constraints in Residential PEMFC Cogeneration: Implications for Dispatch and Electrolyzer Sizing

Tiancheng Fang, Jiwei Wang, Honghao Wang, Baoyi Shen, Zhenyan Ma, Yingliang Yang, Yun Duan, Jingxuan Yang, Guoqing Guan, Abuliti Abudula

Energies · 05.11.2026 · 19 (21) · 5307

DOI: 10.3390/en19215307 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 05.11.2026. Verfasst von Tiancheng Fang und 9 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JST SPRING.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Residential fuel cell cogeneration is usually credited with all its recovered heat, although that heat is useful only if a coincident demand absorbs it. Hourly TRNSYS 18 simulations of an off-grid dwelling in Aomori City, Japan, with a 700 W proton exchange membrane fuel cell running on self-produced hydrogen, compared four dispatch rules, two thermal services and several electrolyzer and store sizes over a periodic year. With space heating, residual heat demand was 12.6 times the electrical deficit after photovoltaic and battery supply. The unit was potentially heat-rich in 88.7–92.3% of deficit hours with hot water alone and 2.2–3.7% with space heating. Against a run without hydrogen, 25–61% of the heat an immersed coil delivered to the store reduced unmet thermal demand where the cycle closed; 22–54% displaced solar heat and 15–22% raised tank losses. Under calendar dispatch with hot water alone, 75% of recovered heat could not pass the coil. Load following raised self-sufficiency from 88.9% to 96.3%, whereas calendar dispatch, and thermally led dispatch with space heating, needed 2.8–5.0 times the producible hydrogen. Electrode areas of 40–110 cm2 gave identical service; each Nm3 of storage was below the seasonal swing of 76.7 Nm3 cost 1.77 kWh of output.

Förderung

  • JST SPRING

Zitieren

APA

Fang, T., Wang, J., Wang, H., Shen, B., Ma, Z., Yang, Y., Duan, Y., Yang, J., Guan, G., & Abudula, A. (2026). Heat-to-Power Matching Constraints in Residential PEMFC Cogeneration: Implications for Dispatch and Electrolyzer Sizing. Energies, 19(21), 5307. https://doi.org/10.3390/en19215307

Vancouver

Fang T, Wang J, Wang H, Shen B, Ma Z, Yang Y, et al. Heat-to-Power Matching Constraints in Residential PEMFC Cogeneration: Implications for Dispatch and Electrolyzer Sizing. Energies. 2026;19(21):5307. doi:10.3390/en19215307

BibTeX
@article{Fang2026,
  author = {Fang, Tiancheng and Wang, Jiwei and Wang, Honghao and Shen, Baoyi and Ma, Zhenyan and Yang, Yingliang and Duan, Yun and Yang, Jingxuan and Guan, Guoqing and Abudula, Abuliti},
  title = {Heat-to-Power Matching Constraints in Residential PEMFC Cogeneration: Implications for Dispatch and Electrolyzer Sizing},