A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage Switchgear
Energies · 04.11.2026 · 19 (21) · 5296
DOI: 10.3390/en19215296 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 04.11.2026. Verfasst von Yujian Zhou und 1 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of CHN Energy Guangtou Beihai Power Generation Co., Ltd..
Abstract (Originalsprache)
Characteristic gas monitoring is an important approach for detecting incipient faults and supporting the intelligent operation and maintenance of high-voltage switchgear. However, existing methods primarily rely on concentration thresholds or steady-state features, making it difficult to simultaneously optimize sensor placement and accurately localize fault-gas sources. To address these limitations, this study proposes a virtual–physical sensing method for fault-gas source localization. A full-scale test platform and a 1:1 three-dimensional numerical model of 10 kV air-insulated switchgear (AIS) were constructed to obtain the time-series responses of CO, CO2, NO, and O3 for different fault-gas source locations. Candidate monitoring points were quantitatively evaluated using a combination of the Welch t-test, mutual information, and entropy difference. Multi-gas features from the selected monitoring points were then fused to identify nine fault-location classes. The results showed that the reported relative errors in final recorded concentrations did not exceed 9.09%; MP8, MP1, and MP2 were the three highest-ranked monitoring locations; under five-fold stratified cross-validation, the accuracy, macro-precision, macro-recall, and macro-F1 score of the random forest model all reached 100%. The proposed method provides a quantitative basis for reducing the number of gas sensors and localizing fault-gas sources in high-voltage switchgear.
Förderung
- Science and Technology Project of CHN Energy Guangtou Beihai Power Generation Co., Ltd.
Zitieren
APA
Zhou, Y., & Luo, H. (2026). A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage Switchgear. Energies, 19(21), 5296. https://doi.org/10.3390/en19215296
Vancouver
Zhou Y, Luo H. A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage Switchgear. Energies. 2026;19(21):5296. doi:10.3390/en19215296
BibTeX
@article{Zhou2026,
author = {Zhou, Yujian and Luo, Hao},
title = {A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage Switchgear},
journal = {Energies},
year = {2026},
volume = {19},
number = {21},
pages = {5296},
doi = {10.3390/en19215296}
}