EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Wind-Induced Fatigue of Substation Disconnect Switchgear Structures

Xiao Zhu, Peng Li, Qianbo Xiao, Min Liu, Shidong Nie, Qian Liu, Ze Wang, Qingshan Yang, Baozhi Liu

Energies · 04.11.2026 · 19 (21) · 5288

DOI: 10.3390/en19215288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 04.11.2026. Verfasst von Xiao Zhu und 8 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The New Chongqing Young Innovative Talent Project of Chongqing Municipal Science and Technology Bureau, Science Fund for Creative Research Groups of the National Natural Science Foundation of China, Research on Wind-Resistant Design Technology for Key Equipment and Circuits of Ultra-High Voltage Converter Stations.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Substation pillar-type switchgear structures are important electrical equipment in the power transmission and transformation system. These structures are characterized by a large top mass, low overall stiffness, and low natural vibration frequency, and are prone to fatigue damage under long-term wind loads. At present, studies on wind-induced vibration fatigue of substation disconnect switch structures are relatively limited. In this paper, a numerical model of the substation disconnect switch structure is established on the basis of static tests, and wind loads are determined according to wind tunnel test results. The Weibull distribution model and the mixed distribution model (Weibull distribution + GPD distribution) are adopted to characterize the wind-speed probability distributions in large-scale steady strong-wind regions and typhoon-prone regions, respectively. Fatigue damage calculation and life prediction are carried out for the fatigue-critical positions of the disconnect switch structure. The results show that the windward and leeward M16 bolts at the flange joint suffer fatigue failure within the 50-year design service life. In large-scale steady strong-wind regions, the predicted fatigue lives of the critical M16-① and M16-⑤ bolts are 8.28 years and 8.48 years, respectively; in typhoon-prone regions, their predicted fatigue lives reduce to 0.87 years and 3.01 years, respectively. The research findings can provide a reference for the anti-fatigue design of flange joints for substation disconnect switch structures.

Förderung

  • The New Chongqing Young Innovative Talent Project of Chongqing Municipal Science and Technology Bureau
  • Science Fund for Creative Research Groups of the National Natural Science Foundation of China
  • Research on Wind-Resistant Design Technology for Key Equipment and Circuits of Ultra-High Voltage Converter Stations

Zitieren

APA

Zhu, X., Li, P., Xiao, Q., Liu, M., Nie, S., Liu, Q., Wang, Z., Yang, Q., & Liu, B. (2026). Research on Wind-Induced Fatigue of Substation Disconnect Switchgear Structures. Energies, 19(21), 5288. https://doi.org/10.3390/en19215288

Vancouver

Zhu X, Li P, Xiao Q, Liu M, Nie S, Liu Q, et al. Research on Wind-Induced Fatigue of Substation Disconnect Switchgear Structures. Energies. 2026;19(21):5288. doi:10.3390/en19215288

BibTeX
@article{Zhu2026,
  author = {Zhu, Xiao and Li, Peng and Xiao, Qianbo and Liu, Min and Nie, Shidong and Liu, Qian and Wang, Ze and Yang, Qingshan and Liu, Baozhi},
  title = {Research on Wind-Induced Fatigue of Substation Disconnect Switchgear Structures},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {5288},
  doi = {10.3390/en19215288}
}
Kostenlos starten →