Maintenance Service Capacity Boundaries for Multi-Stack Solid Oxide Fuel Cell Systems

Sensen Fan, Yaqing He, Canguan Gao, Shuang Xue, Jinshan Su, Heng Wang, Yingtian Chi

Energies · 29.10.2026 · 19 (21) · 5157

DOI: 10.3390/en19215157 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 29.10.2026. Verfasst von Sensen Fan und 6 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Yili Normal University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Modular solid oxide fuel cell systems can support partial maintenance during power generation. Existing capacity assessments may overlook reserve withdrawal when a maintained stack leaves its healthy-reserve role. A maintenance service capacity criterion is proposed to account for normal-output reduction and reserve withdrawal. First, normal, maintenance, and healthy-reserve role responses are characterized under uniform and nonuniform hydrogen supply. Second, output reduction and reserve withdrawal are combined into a maintenance-induced capacity loss. Then, object-exchange relations, conditions for identity-independent capacity, and guaranteed and selectable service-window boundaries are derived. Finally, simultaneous responses test composability, and analytical extensions examine general multi-stack maintenance sets. The results show that maintaining A rather than B gives normalized capacity differences of 0.0493 and 0.0891 under 45:55 and 40:60 hydrogen supply, respectively. In the four-stack analytical extension, object selection raises the maintainable count from two to three at the same resource budget. The criterion links maintenance planning to the output available throughout the required service interval.

Förderung

  • Yili Normal University

Zitieren

APA

Fan, S., He, Y., Gao, C., Xue, S., Su, J., Wang, H., & Chi, Y. (2026). Maintenance Service Capacity Boundaries for Multi-Stack Solid Oxide Fuel Cell Systems. Energies, 19(21), 5157. https://doi.org/10.3390/en19215157

Vancouver

Fan S, He Y, Gao C, Xue S, Su J, Wang H, et al. Maintenance Service Capacity Boundaries for Multi-Stack Solid Oxide Fuel Cell Systems. Energies. 2026;19(21):5157. doi:10.3390/en19215157

BibTeX
@article{Fan2026,
  author = {Fan, Sensen and He, Yaqing and Gao, Canguan and Xue, Shuang and Su, Jinshan and Wang, Heng and Chi, Yingtian},
  title = {Maintenance Service Capacity Boundaries for Multi-Stack Solid Oxide Fuel Cell Systems},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {5157},
  doi = {10.3390/en19215157}
}