Active Fault-Tolerant Control for DFIG-Based Wind Energy Conversion Systems Using a Sensor FDI and a Novel Reconfiguration Framework

Naziha Chouider, Karim Beddek, Emad Abd-Elrady, Karim Benalia, Mohamed Zerrougui, Rezki Haddouche, Hamed Aly, Mohamed I. Mosaad

Energies · 22.10.2026 · 19 (21) · 5033

DOI: 10.3390/en19215033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 22.10.2026. Verfasst von Naziha Chouider und 7 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Doubly Fed Induction Generator (DFIG)-based Wind Energy Conversion Systems (WECSs) rely on accurate sensor measurements to ensure stable operation and effective power conversion. However, sensor faults can compromise control performance and system reliability and lead to unscheduled shutdowns if they are not promptly detected and accommodated. This paper presents an Active Fault-Tolerant Control (AFTC) framework for a grid-connected DFIG-based WECS, integrating an existing sensor Fault Detection and Isolation (FDI) methodology with a novel control reconfiguration framework. The inherited FDI module detects and isolates sensor faults, while the proposed reconfiguration framework automatically selects an appropriate compensation strategy according to the number of simultaneously faulty sensors. Pure Measurement Compensation (PMC), Hybrid Measurement-Estimation Compensation (HMEC), and Pure Estimation Compensation (PEC) are employed for single-, double-, and triple-sensor fault scenarios, respectively. These strategies replace or reconstruct faulty sensor measurements within the affected control loops using available healthy or estimated signals. The proposed framework is implemented in MATLAB/Simulink and evaluated under additive and multiplicative sensor fault scenarios. The decision function reaches the detection threshold approximately 0.4 ms after fault injection, while the effective fault identification and isolation signal is activated within approximately 2.4 ms, followed by the activation of the corresponding compensation strategy. The simulation results demonstrate that the proposed reconfiguration strategies for the AFTC framework maintain continuous converter operation and satisfactory dynamic performance following fault diagnosis. The proposed framework provides a structured approach to active control reconfiguration for improved reliability and resilience to faults in DFIG-based WECSs.

Zitieren

APA

Chouider, N., Beddek, K., Abd-Elrady, E., Benalia, K., Zerrougui, M., Haddouche, R., Aly, H., & Mosaad, M. I. (2026). Active Fault-Tolerant Control for DFIG-Based Wind Energy Conversion Systems Using a Sensor FDI and a Novel Reconfiguration Framework. Energies, 19(21), 5033. https://doi.org/10.3390/en19215033

Vancouver

Chouider N, Beddek K, Abd-Elrady E, Benalia K, Zerrougui M, Haddouche R, et al. Active Fault-Tolerant Control for DFIG-Based Wind Energy Conversion Systems Using a Sensor FDI and a Novel Reconfiguration Framework. Energies. 2026;19(21):5033. doi:10.3390/en19215033

BibTeX
@article{Chouider2026,
  author = {Chouider, Naziha and Beddek, Karim and Abd-Elrady, Emad and Benalia, Karim and Zerrougui, Mohamed and Haddouche, Rezki and Aly, Hamed and Mosaad, Mohamed I.},
  title = {Active Fault-Tolerant Control for DFIG-Based Wind Energy Conversion Systems Using a Sensor FDI and a Novel Reconfiguration Framework},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {5033},
  doi = {10.3390/en19215033}
}
Kostenlos starten →