Complex-Network-Guided High-Risk Substation Identification and Targeted Mitigation of Transformer DC Bias in Multi-Infeed UHVDC Receiving-End Grids
Energies · 18.08.2026 · 19 (16) · 3866
DOI: 10.3390/en19163866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 18.08.2026. Verfasst von Jingbo Song und 8 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Henan Economic Research Institute.
Abstract (Originalsprache)
In multi-infeed UHVDC receiving-end grids, transformer DC-bias risk is affected not only by the magnitude of grounding-electrode current, but also by the AC-grid topology, substation grounding condition, voltage-level-dependent current limits, and polarity coordination among grounding electrodes. Conventional single-electrode or magnitude-only assessments may therefore fail to identify the substations that require priority mitigation. This paper proposes a full-registry high-risk substation identification and targeted mitigation framework for transformer DC bias in multi-infeed UHVDC receiving-end grids. A field–circuit coupling model is established using the earth-resistivity model, grounding-electrode parameters, substation grounding parameters, transformer winding DC resistances, and AC-grid topology. To address earth-resistivity uncertainty, a measurement-based correction procedure is introduced and verified by an engineering field-measurement case. On this basis, the receiving-end grid is represented as a weighted complex network, and high-risk substations are identified by jointly considering network importance, voltage-dependent limits, multi-mode DC-bias exposure, and over-limit severity. A case study with 898 substations is carried out under four representative grounding-electrode operating modes. The results show that CJ single-electrode operation produces no over-limit substation, whereas YZ single-electrode, same-polarity two-electrode, and opposite-polarity two-electrode operation produce 2, 3, and 2 over-limit substations, respectively. Polarity coordination changes the risk pattern: same-polarity operation mainly aggravates the UHV substations NY UHV and ZMD UHV, whereas opposite-polarity operation relieves them but concentrates the 500 kV risk at SMPP and ZT. Guided by the high-risk ranking, installing 2 Ω neutral-point resistors at only two over-limit 500 kV substations reduces the currents at ZT and SMPP from 5.26 A and 5.68 A to 2.55 A and 0.58 A, respectively, bringing all evaluated substations within their limits and avoiding system-wide retrofitting.
Förderung
- State Grid Henan Economic Research Institute
Zitieren
APA
Song, J., Qi, H., Chen, C., Zhang, L., Yan, X., Zhang, J., Yang, B., Lan, L., & Li, Y. (2026). Complex-Network-Guided High-Risk Substation Identification and Targeted Mitigation of Transformer DC Bias in Multi-Infeed UHVDC Receiving-End Grids. Energies, 19(16), 3866. https://doi.org/10.3390/en19163866
Vancouver
Song J, Qi H, Chen C, Zhang L, Yan X, Zhang J, et al. Complex-Network-Guided High-Risk Substation Identification and Targeted Mitigation of Transformer DC Bias in Multi-Infeed UHVDC Receiving-End Grids. Energies. 2026;19(16):3866. doi:10.3390/en19163866
BibTeX
@article{Song2026,
author = {Song, Jingbo and Qi, Huanruo and Chen, Chen and Zhang, Liang and Yan, Xiangyang and Zhang, Jinfeng and Yang, Bochao and Lan, Lei and Li, Yuanjie},
title = {Complex-Network-Guided High-Risk Substation Identification and Targeted Mitigation of Transformer DC Bias in Multi-Infeed UHVDC Receiving-End Grids},
journal = {Energies},
year = {2026},
volume = {19},
number = {16},
pages = {3866},
doi = {10.3390/en19163866}
}
EUVIMED