RDA-ANN Based Real-Time Selective Harmonic Elimination in Multilevel Inverter Fed by PV Panels

Hulusi Karaca, Mehmet Akif Şahman, Yasin Bektaş

Energies · 17.08.2026 · 19 (16) · 3849

DOI: 10.3390/en19163849 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 17.08.2026. Verfasst von Hulusi Karaca und 2 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work presents a novel method known as the Red Deer Algorithm-Based Artificial Neural Network (RDA-ANN) for managing real-time voltage and harmonic control in a cascade H-bridge multilevel inverter (CHB-MLI) that is fed by photovoltaic (PV) panels. The RDA-ANN technique proposed here computes the switching angles in real-time for selective harmonic elimination (SHE) on the output voltage of a multilevel inverter (MLI). In the proposed approach, a comprehensive lookup table containing 7776 permutations of switching angles was first generated offline using RDA optimization for a three-phase, 11-level CHB-MLI with five PV panels operating across a voltage range of 30 V to 35 V. This dataset was subsequently used to train a feed-forward ANN model capable of predicting optimal switching angles corresponding to any real-time voltage measurements from the panels. The SHE-PWM approach based on RDA-ANN targets the elimination of the 5th, 7th, 11th, and 13th order harmonics. This algorithm guarantees that the intended fundamental voltage is achieved, even during fluctuations in the voltages of the panels caused by varying irradiation and temperature conditions, while effectively removing the unwanted harmonics. The findings, validated under multiple environmental scenarios, illustrate that the RDA-ANN-based SHE-PWM technique successfully eliminates the selected harmonics from the load voltage with a fundamental voltage error not exceeding 0.18%, and results in a low total harmonic distortion (THD) value that complies with the IEEE 519-2022 standard across all tested conditions.

Zitieren

APA

Karaca, H., Şahman, M. A., & Bektaş, Y. (2026). RDA-ANN Based Real-Time Selective Harmonic Elimination in Multilevel Inverter Fed by PV Panels. Energies, 19(16), 3849. https://doi.org/10.3390/en19163849

Vancouver

Karaca H, Şahman MA, Bektaş Y. RDA-ANN Based Real-Time Selective Harmonic Elimination in Multilevel Inverter Fed by PV Panels. Energies. 2026;19(16):3849. doi:10.3390/en19163849

BibTeX
@article{Karaca2026,
  author = {Karaca, Hulusi and Şahman, Mehmet Akif and Bektaş, Yasin},
  title = {RDA-ANN Based Real-Time Selective Harmonic Elimination in Multilevel Inverter Fed by PV Panels},