Improving ADRC Strategy for DC-Link Voltage Regulation in PV Grid-Tied Four-Leg Inverters Using an Adaptive Nonlinear High-Gain Observer
Energies · 05.08.2026 · 19 (15) · 3679
DOI: 10.3390/en19153679 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 05.08.2026. Verfasst von Mourad Zebboudj und 7 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: G2Elab laboratory, University Grenoble Alpes, CNRS, Grenoble France.
Abstract (Originalsprache)
In practical photovoltaic grid-tied four-leg inverter systems (PV-GTFLIs), changes in radiation, temperature, and grid voltage magnitude cause significant disturbances, including DC-link voltage disturbance and power unbalance, which can impact the system’s dynamic responses, control performance, grid power quality, efficiency, and reliability. To deal with these problems, this article proposes an improved active disturbance rejection control (ADRC) methodology for optimizing DC-link voltage regulation in PV-GTFLIs. The proposed ADRC approach incorporates a nonlinear high-gain observer (NHGO) within the external DC-link voltage control loop to estimate and mitigate disturbances. The suggested ADRC approach adopts the NHGO instead of the traditional extended state observer due to its superior characteristics, which include excellent dynamic responses, rapid and accurate disturbance estimation and rejection, and enhanced resilience against measurement noise. Thus, it enhances the stability of the DC bus voltage, enhances the system’s dynamic responses, improves its steady-state performance, increases its ability to reject voltage disturbances, and improves the reliability of the PV-GTFLI, as well as reducing the cost and size. The effectiveness of the proposed ADRC approach based on the NHGO is confirmed through software-in-the-loop real-time validation tests, including changes in irradiation and PV cell temperature, sag in grid voltage amplitude, and internal uncertainties, using the OPAL real-time digital simulator.
Förderung
- G2Elab laboratory, University Grenoble Alpes, CNRS, Grenoble France
Zitieren
APA
Zebboudj, M., Rekioua, T., Chebabhi, A., Bacha, S., Ihammouchen, S., Sadli, I., Rekioua, D., & Frey, D. (2026). Improving ADRC Strategy for DC-Link Voltage Regulation in PV Grid-Tied Four-Leg Inverters Using an Adaptive Nonlinear High-Gain Observer. Energies, 19(15), 3679. https://doi.org/10.3390/en19153679
Vancouver
Zebboudj M, Rekioua T, Chebabhi A, Bacha S, Ihammouchen S, Sadli I, et al. Improving ADRC Strategy for DC-Link Voltage Regulation in PV Grid-Tied Four-Leg Inverters Using an Adaptive Nonlinear High-Gain Observer. Energies. 2026;19(15):3679. doi:10.3390/en19153679
BibTeX
@article{Zebboudj2026,
author = {Zebboudj, Mourad and Rekioua, Toufik and Chebabhi, Ali and Bacha, Seddik and Ihammouchen, Syphax and Sadli, Idris and Rekioua, Djamila and Frey, David},
title = {Improving ADRC Strategy for DC-Link Voltage Regulation in PV Grid-Tied Four-Leg Inverters Using an Adaptive Nonlinear High-Gain Observer},
journal = {Energies},
year = {2026},
volume = {19},
number = {15},
pages = {3679},
doi = {10.3390/en19153679}
}