EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical Analysis of Flow Conditions Inside an Impulse Turbine Under Reciprocating Flow

Muhamad Aiman Jalani, Hiroto Shinohara, Yasutaka Imai

Energies · 10.07.2026 · 19 (14) · 3250

DOI: 10.3390/en19143250 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 10.07.2026. Verfasst von Muhamad Aiman Jalani und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Saga University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oscillating water column wave energy converters require self-rectifying turbines capable of maintaining stable performance under bidirectional airflow. This study numerically investigates the aerodynamic performance and internal flow characteristics of an axial-flow impulse turbine using OpenFOAM under both uniform and reciprocating airflow conditions. Rotor motion was modeled using the Multiple Reference Frame approach, and the numerical model was validated against experimental data for one-way flow at an inlet velocity of 8.71 m s−1 and rotational speeds ranging from 300 to 1300 rpm. The CFD results successfully reproduced the experimental efficiency trend, yielding a peak efficiency of η = 0.4269 at 700 rpm and ϕ ≈ 0.95, which closely aligns with the experimental peak efficiency of η = 0.4425. Validation metrics demonstrated a high degree of accuracy, with an RMSE of 0.0219, a mean absolute error of 0.0197, a maximum absolute error of 0.0399, a squared Pearson correlation coefficient of 0.826, and a peak-efficiency difference of 3.5%. Flow-field analysis revealed that low rotational speeds resulted in high outlet velocities and incomplete energy extraction, whereas excessive rotational speeds caused flow misalignment, downstream vortex formation, and additional aerodynamic losses. Under reciprocating flow conditions, characterized by a sinusoidal velocity amplitude of 8.71 m s−1 and periods of 0.5–2.0 s at 700 rpm, both input and torque coefficients exhibited hysteresis, with the strongest loops observed at the shortest periods. Examinations of streamline, pressure, and velocity distributions indicated that residual flow during flow reversal alters the effective inlet direction in the subsequent half-cycle, resulting in flow memory and a phase-dependent turbine response. As the present computational domain excludes the OWC chamber, these findings characterize turbine-level aerodynamic performance rather than the complete system power coefficient.

Förderung

  • Saga University

Zitieren

APA

Jalani, M. A., Shinohara, H., & Imai, Y. (2026). Numerical Analysis of Flow Conditions Inside an Impulse Turbine Under Reciprocating Flow. Energies, 19(14), 3250. https://doi.org/10.3390/en19143250

Vancouver

Jalani MA, Shinohara H, Imai Y. Numerical Analysis of Flow Conditions Inside an Impulse Turbine Under Reciprocating Flow. Energies. 2026;19(14):3250. doi:10.3390/en19143250

BibTeX
@article{Jalani2026,
  author = {Jalani, Muhamad Aiman and Shinohara, Hiroto and Imai, Yasutaka},
  title = {Numerical Analysis of Flow Conditions Inside an Impulse Turbine Under Reciprocating Flow},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {14},
  pages = {3250},
  doi = {10.3390/en19143250}
}
Kostenlos starten →