Experimental Comparison of Sensible and Latent Heat Storage in a Packed-Bed Thermal Energy Storage System
Energies · 06.07.2026 · 19 (13) · 3196
DOI: 10.3390/en19133196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 06.07.2026. Verfasst von Tomasz Spietz und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission.
Abstract (Originalsprache)
Thermal energy storage (TES) is essential for improving the flexibility and efficiency of renewable and industrial energy systems. This study experimentally compares sensible and latent heat storage using basalt aggregate and an encapsulated phase change material (PCM), specifically 60 wt.% NaNO3–40 wt.% KNO3, as packed-bed materials under elevated-temperature operating conditions. Tests were conducted in an air-based TES rig at air flow rates of 60–120 kg/h, with packed bed temperatures exceeding 400 °C. Key parameters included temperature profiles, thermal power, energy storage, and recovery during charging and discharging phases. The results indicate that increasing the air flow rate accelerated thermal front propagation and improved charging and discharging power, but did not proportionally increase stored or recovered energy. The basalt bed achieved recovered volumetric energy densities of 108–160 MJ/m3 at about 150 °C and 351–405 MJ/m3 above 320 °C. The encapsulated solar salt bed reached higher values, from 412–508 MJ/m3 near 290 °C to 523–626 MJ/m3 at higher temperatures. Both materials showed high TES efficiencies, in the range of 80–94%. Encapsulated PCM significantly increased energy storage density in packed-bed TES systems, while basalt aggregate provides higher short-term thermal power output.
Förderung
- European Commission
Zitieren
APA
Spietz, T., Dobras, S., Kulik, K., Fryza, R., & Czardybon, A. (2026). Experimental Comparison of Sensible and Latent Heat Storage in a Packed-Bed Thermal Energy Storage System. Energies, 19(13), 3196. https://doi.org/10.3390/en19133196
Vancouver
Spietz T, Dobras S, Kulik K, Fryza R, Czardybon A. Experimental Comparison of Sensible and Latent Heat Storage in a Packed-Bed Thermal Energy Storage System. Energies. 2026;19(13):3196. doi:10.3390/en19133196
BibTeX
@article{Spietz2026,
author = {Spietz, Tomasz and Dobras, Szymon and Kulik, Kinga and Fryza, Rafał and Czardybon, Agata},
title = {Experimental Comparison of Sensible and Latent Heat Storage in a Packed-Bed Thermal Energy Storage System},
journal = {Energies},
year = {2026},
volume = {19},
number = {13},
pages = {3196},
doi = {10.3390/en19133196}
}
EUVIMED