Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding
Energies · 30.06.2026 · 19 (13) · 3091
DOI: 10.3390/en19133091 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 30.06.2026. Verfasst von Rukiye B.Aymaz und 3 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Türkiye.
Abstract (Originalsprache)
The increasing integration of renewable energy sources, high-voltage direct current (HVDC) and power-electronics-based equipment has intensified the exposure of transformer windings to high-frequency voltage components, steep-front transients and high-dv/dt stresses, highlighting the need for detailed high-frequency winding models. This study presents a high-frequency model of a six-section winding assembly corresponding to one phase of a 10 kV/0.41 kV, Dyn11, 2500 kVA distribution transformer. The winding assembly was experimentally investigated under coreless conditions using frequency response analysis (FRA) measurements over the frequency range of 20 Hz–2 MHz. Frequency-dependent resistance R(f) parameters were extracted from finite element method (FEM)-based electromagnetic field analyses, while the self- and mutual inductance matrix and the capacitance parameters were obtained from electromagnetic and electrostatic field solutions, respectively. The resulting segmented resistance–inductance–mutual inductance–capacitance (R-L-M-C) equivalent circuit model was solved in the frequency domain using Modified Nodal Analysis (MNA). Before the FRA-based validation, the low-frequency consistency of the model was checked at 50.431 Hz, where the calculated and measured magnitudes differed by only 0.1074 dB. Over the common frequency range, the model achieved a root mean square error (RMSE) of 3.09 dB and a mean absolute error (MAE) of 1.76 dB. The results show that the proposed field-extracted model can represent the overall FRA trend, the dominant attenuation region and the main resonance/anti-resonance characteristics of the winding assembly, although deviations remain around sharp resonance points.
Förderung
- Scientific and Technological Research Council of Türkiye
Zitieren
APA
B.Aymaz, R., Demirol, Y. B., Tekdemir, İ. G., & Alboyaci, B. (2026). Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding. Energies, 19(13), 3091. https://doi.org/10.3390/en19133091
Vancouver
B.Aymaz R, Demirol YB, Tekdemir İG, Alboyaci B. Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding. Energies. 2026;19(13):3091. doi:10.3390/en19133091
BibTeX
@article{BAymaz2026,
author = {B.Aymaz, Rukiye and Demirol, Yunus Berat and Tekdemir, İbrahim Gürsu and Alboyaci, Bora},
title = {Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding},
journal = {Energies},
year = {2026},
volume = {19},
number = {13},
pages = {3091},
doi = {10.3390/en19133091}
}