Fachartikel in der Zeitschrift Energies, online erschienen am 26.06.2026. Verfasst von Obed Muhayimana und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education Youth and Sports.
Abstract (Originalsprache)
Accurate fault location is essential for rapid service restoration in distribution networks. However, modern active distribution networks (ADNs) with high penetration of distributed energy resources (DERs) challenge conventional methods through multi-source fault contributions, bidirectional power flows, and converter-limited fault currents. This paper presents a time-domain fault location method for both passive distribution networks (PDNs) and ADNs, based on a three-sample apparent inductance estimator that uses local voltage and current measurements. The estimator exploits the strong correlation between line inductance and fault distance, with reduced sensitivity to fault resistance compared with classical impedance approaches. Its performance was evaluated on a 22 kV, 20 km distribution feeder, covering three fault types, four fault resistance levels (5–500 Ω), four fault locations, EN 50160 standard-compliant harmonic distortion, and DER penetration levels from 0 to 80%. Under ideal sinusoidal conditions, relative location errors remained below 2% for low-resistance faults. In ADNs, the method achieved errors below 5% for low-resistance faults across all fault types, with accuracy decreasing for high-resistance faults at high DER penetration. A sensitivity analysis confirmed robustness across the tested simulation conditions, covering the SNR, load current, THD, and DER penetration.
Förderung
- Ministry of Education Youth and Sports
Zitieren
APA
Muhayimana, O., Toman, P., Lehtonen, M., Aljazaeri, A., Li, H., & Tuyishime, S. (2026). Fault Location in Distribution Networks Using Apparent-Inductance-Based Algorithm. Energies, 19(13), 3027. https://doi.org/10.3390/en19133027
Vancouver
Muhayimana O, Toman P, Lehtonen M, Aljazaeri A, Li H, Tuyishime S. Fault Location in Distribution Networks Using Apparent-Inductance-Based Algorithm. Energies. 2026;19(13):3027. doi:10.3390/en19133027
BibTeX
@article{Muhayimana2026,
author = {Muhayimana, Obed and Toman, Petr and Lehtonen, Matti and Aljazaeri, Ali and Li, He and Tuyishime, Silas},
title = {Fault Location in Distribution Networks Using Apparent-Inductance-Based Algorithm},
journal = {Energies},
year = {2026},
volume = {19},
number = {13},
pages = {3027},
doi = {10.3390/en19133027}
}
EUVIMED