Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 20.06.2026. Verfasst von Zhishuai Hu und 3 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia, First-Class Disciplines Research Excellence Program of Inner Mongolia Autonomous Region.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Under weak-grid conditions, grid-following (GFL) control of doubly fed induction generators (DFIGs) suffers from reduced stability margins, deteriorated dynamic performance, and intensified oscillations near the stability boundary. To address these issues, a pre-synchronized switching strategy between GFL and grid-forming (GFM) modes, triggered by locally measured operating variables, is proposed. Based on the GFL control model, the evolution of system dynamics with decreasing short-circuit ratio is analyzed, thereby elucidating how reduced grid strength progressively weakens robustness and disturbance rejection and eventually leads to instability. To characterize this deterioration, a set of normalized indices is constructed to quantify the oscillation levels of active power, phase-locked loop frequency, and point of common coupling voltage, enabling reliable identification of control-performance deterioration. A pre-synchronization scheme based on a virtual power closed loop is then developed, allowing the target mode to converge to the current operating point prior to takeover and enabling smooth bidirectional switching between GFL and GFM modes. Hardware-in-the-loop results demonstrate that the proposed strategy accurately detects GFL performance deterioration and effectively suppresses boundary oscillations while mitigating switching transients, thereby enhancing the adaptability of DFIGs to variations in grid strength.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Inner Mongolia
  • First-Class Disciplines Research Excellence Program of Inner Mongolia Autonomous Region
  • Key R&D and Achievement Transformation Project of Inner Mongolia Autonomous Region

Zitieren

APA

Hu, Z., Lang, Y., Fang, C., & Ren, Y. (2026). A Pre-Synchronized GFL/GFM Switching Method Triggered by Local Operating Indicators for DFIG Wind Turbines Under Weak-Grid Conditions. Energies, 19(12), 2924. https://doi.org/10.3390/en19122924

Vancouver

Hu Z, Lang Y, Fang C, Ren Y. A Pre-Synchronized GFL/GFM Switching Method Triggered by Local Operating Indicators for DFIG Wind Turbines Under Weak-Grid Conditions. Energies. 2026;19(12):2924. doi:10.3390/en19122924

BibTeX
@article{Hu2026,
  author = {Hu, Zhishuai and Lang, Yongyi and Fang, Chenzhi and Ren, Yongfeng},
  title = {A Pre-Synchronized GFL/GFM Switching Method Triggered by Local Operating Indicators for DFIG Wind Turbines Under Weak-Grid Conditions},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {12},
  pages = {2924},
  doi = {10.3390/en19122924}
}
Kostenlos starten →