Fachartikel in der Zeitschrift Energies, online erschienen am 10.06.2026. Verfasst von Xuyan Xu und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Guangdong Provincial University Youth Innovation Talent Program, Foshan Innovation Research Project.
Abstract (Originalsprache)
This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation.
Förderung
- National Natural Science Foundation of China
- Guangdong Provincial University Youth Innovation Talent Program
- Foshan Innovation Research Project
Zitieren
APA
Xu, X., Zhang, T., Li, D., Sun, W., Wu, Z., & Xu, Y. (2026). A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency. Energies, 19(12), 2787. https://doi.org/10.3390/en19122787
Vancouver
Xu X, Zhang T, Li D, Sun W, Wu Z, Xu Y. A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency. Energies. 2026;19(12):2787. doi:10.3390/en19122787
BibTeX
@article{Xu2026,
author = {Xu, Xuyan and Zhang, Tao and Li, Dongming and Sun, Wanchun and Wu, Zhijiang and Xu, Yansheng},
title = {A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency},
journal = {Energies},
year = {2026},
volume = {19},
number = {12},
pages = {2787},
doi = {10.3390/en19122787}
}