Study on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors
Energies · 08.06.2026 · 19 (12) · 2758
DOI: 10.3390/en19122758 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 08.06.2026. Verfasst von Shuangyin He und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 2025 Science and Technology Program of Inner Mongolia Power (Group) Co., Ltd., Natural Science Foundation of Inner Mongolia Autonomous Region, Inner Mongolia University of Technology Graduate School–Enterprise Cooperation Course Construction Project.
Abstract (Originalsprache)
To address the difficulty of directly measuring the internal conductor temperature and the complex influence of external environmental factors on gas-insulated switchgear (GIS), a three-dimensional thermal–fluid multiphysics coupling model was developed for a 110 kV three-phase common-enclosure GIS disconnect switch. The model incorporates contact resistance heating, natural convection of SF6 gas, wind speed, and solar radiation. The effects of contact resistance and environmental factors on the temperature field distribution were systematically investigated. The results show that an increase in contact resistance significantly raises the conductor temperature, while higher wind speeds effectively reduce the temperature rise of the equipment. Solar radiation substantially increases the enclosure temperature, whereas ambient temperature has little influence on temperature rise. Based on the enclosure temperature rise, a conductor temperature-rise prediction model and a multi-factor correction model were established. Validation results indicate that all models achieved coefficients of determination greater than 0.98, with prediction errors controlled within ±2 °C. The proposed method enables the accurate prediction of conductor temperature under complex environmental conditions and provides technical support for condition monitoring and overheating fault diagnosis of GIS equipment.
Förderung
- 2025 Science and Technology Program of Inner Mongolia Power (Group) Co., Ltd.
- Natural Science Foundation of Inner Mongolia Autonomous Region
- Inner Mongolia University of Technology Graduate School–Enterprise Cooperation Course Construction Project
- Project “Research and Demonstration of an Intelligent Multi-Domain Assessment System for Power Transformers in New-Type Power Systems”
Zitieren
APA
He, S., Zhao, J., Qin, C., Cui, G., & Han, B. (2026). Study on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors. Energies, 19(12), 2758. https://doi.org/10.3390/en19122758
Vancouver
He S, Zhao J, Qin C, Cui G, Han B. Study on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors. Energies. 2026;19(12):2758. doi:10.3390/en19122758
BibTeX
@article{He2026,
author = {He, Shuangyin and Zhao, Jianli and Qin, Chunxu and Cui, Guowei and Han, Bing},
title = {Study on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors},
journal = {Energies},
year = {2026},
volume = {19},
number = {12},
pages = {2758},
doi = {10.3390/en19122758}
}