Energy Efficiency and Disinfection Performance of Plasma-Pulse Water Treatment by High-Voltage Underwater Spark Discharge

Kulzhan M. Shaimerdenova, Nazgul K. Tanasheva, Saule E. Sakipova, Saniya E. Suleimenova, Akerke Rakhmankyzy, Nurgul N. Shuyushbayeva, Ingkar E. Aldabergen, Aizhan K. Salkeyeva, Arailym D. Bozayeva

Energies · 30.05.2026 · 19 (11) · 2647

DOI: 10.3390/en19112647 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 30.05.2026. Verfasst von Kulzhan M. Shaimerdenova und 8 weiteren Autor:innen. Die Arbeit nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Republic of Kazakhstan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Plasma-pulse water treatment using a high-voltage underwater spark discharge is a reagent-free approach with potential for simultaneous disinfection and physicochemical modification of water. In this study, a laboratory-scale recirculating reactor (Vtot = 10 L) equipped with a storage capacitor of C = 0.25 μF was operated at U = 15–30 kV and a pulse repetition frequency of about 1.8 Hz to evaluate disinfection performance and system-level energy characteristics for two water matrices, surface wastewater and tap water. The corresponding calculated capacitor-stored energy ranged from 28.1 to 112.5 J per pulse. Microbiological and physicochemical measurements were performed in triplicate. At U = 30 kV, the total microbial count in wastewater decreased from approximately 1 × 105 CFU/mL to below the method detection limit (LOD = 1 CFU/mL) within 2–3 min. For the 2 min/10 L operating mode, the system-level specific energy input was estimated at 6.7 kWh/m3. During the initial treatment period, temperature-compensated conductivity (σ25) decreased by 3–8%, depending on the water matrix, and then increased with prolonged treatment. These results show that the tested reactor can provide rapid reagent-free reduction in culturable microflora under the studied conditions. However, plasma-pulse treatment should be regarded primarily as an advanced treatment, polishing, or pre-treatment option for complex water matrices rather than as a universal replacement for conventional large-volume disinfection technologies.

Förderung

  • Ministry of Science and Higher Education of the Republic of Kazakhstan

Zitieren

APA

Shaimerdenova, K. M., Tanasheva, N. K., Sakipova, S. E., Suleimenova, S. E., Rakhmankyzy, A., Shuyushbayeva, N. N., Aldabergen, I. E., Salkeyeva, A. K., & Bozayeva, A. D. (2026). Energy Efficiency and Disinfection Performance of Plasma-Pulse Water Treatment by High-Voltage Underwater Spark Discharge. Energies, 19(11), 2647. https://doi.org/10.3390/en19112647

Vancouver

Shaimerdenova KM, Tanasheva NK, Sakipova SE, Suleimenova SE, Rakhmankyzy A, Shuyushbayeva NN, et al. Energy Efficiency and Disinfection Performance of Plasma-Pulse Water Treatment by High-Voltage Underwater Spark Discharge. Energies. 2026;19(11):2647. doi:10.3390/en19112647

BibTeX
@article{Shaimerdenova2026,
  author = {Shaimerdenova, Kulzhan M. and Tanasheva, Nazgul K. and Sakipova, Saule E. and Suleimenova, Saniya E. and Rakhmankyzy, Akerke and Shuyushbayeva, Nurgul N. and Aldabergen, Ingkar E. and Salkeyeva, Aizhan K. and Bozayeva, Arailym D.},
  title = {Energy Efficiency and Disinfection Performance of Plasma-Pulse Water Treatment by High-Voltage Underwater Spark Discharge},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {11},
  pages = {2647},
  doi = {10.3390/en19112647}
}
Kostenlos starten →