Data-Driven Physics-Informed LSTM for Voltage Regulation in Active Distribution Networks
Energies · 28.05.2026 · 19 (11) · 2609
DOI: 10.3390/en19112609 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 28.05.2026. Verfasst von Htutzaw Hein und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Smart-Grid National Science and Technology Major Project, National Natural Science Foundation of China, Guangdong Basic and Applied Basic Research Foundation.
Abstract (Originalsprache)
The rapid integration of photovoltaic (PV) generation into active distribution networks (ADNs) creates a fundamental tension between maintaining tight voltage regulation and accommodating high distributed energy resource (DER) penetration levels. Conventional voltage control methods such as the droop control operate locally without coordination, while centralized optimal power flow requires full network observability and reliable real-time communication. Multi-agent deep reinforcement learning (MADRL) methods provide adaptive coordination but suffer from long training times and algorithmic complexity that prevent direct deployment on embedded inverter hardware. This paper proposes the Optimal Historical Selection and Forecasting (OHSF) scheme: a physics-informed long short-term memory (LSTM) network combined with an online sensitivity-based correction loop for medium-voltage ADNs. A composite loss function incorporating data-driven regression, an inter-PV voltage sensitivity penalty, and an inverter capability constraint produces reactive power setpoints that are inherently aware of physical limits, while the correction loop refines the predictions using real-time AC power flow feedback. The OHSF scheme supports a centralized full-network mode and a decentralized fallback mode in which the trained weights run locally on each inverter. Simulations under worst-case PV placement and network reconfiguration on the modified IEEE 33-bus and 69-bus test systems achieve an average voltage deviation across all PV buses of 0.701% and 0.601% at 172% DER penetration on the 33-bus system, and 0.804% and 0.806% at 242% DER penetration on the 69-bus system, while training 32 to 49 times faster than state-of-the-art MADRL methods.
Förderung
- Smart-Grid National Science and Technology Major Project
- National Natural Science Foundation of China
- Guangdong Basic and Applied Basic Research Foundation
Zitieren
APA
Hein, H., Yu, H., Yu, L., & Deng, Z. (2026). Data-Driven Physics-Informed LSTM for Voltage Regulation in Active Distribution Networks. Energies, 19(11), 2609. https://doi.org/10.3390/en19112609
Vancouver
Hein H, Yu H, Yu L, Deng Z. Data-Driven Physics-Informed LSTM for Voltage Regulation in Active Distribution Networks. Energies. 2026;19(11):2609. doi:10.3390/en19112609
BibTeX
@article{Hein2026,
author = {Hein, Htutzaw and Yu, Haifeng and Yu, Lujie and Deng, Zhaoshun},
title = {Data-Driven Physics-Informed LSTM for Voltage Regulation in Active Distribution Networks},
journal = {Energies},
year = {2026},
volume = {19},
number = {11},
pages = {2609},
doi = {10.3390/en19112609}
}
EUVIMED