Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems
Energies · 21.05.2026 · 19 (10) · 2468
DOI: 10.3390/en19102468 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 21.05.2026. Verfasst von Gourab Schmidt-Banerjee und 2 weiteren Autor:innen. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Federal Ministry of Education and Research, University of Kassel.
Abstract (Originalsprache)
Multiple-fault events can initiate overload propagation and cascading outages, resulting in severe load loss and reduced system resilience. Therefore, beyond conventional protection concepts based on the (n − 1) criterion, there is also a need to address multiple-fault events to minimize loss of load. This paper presents an optimized overload tripping scheme to mitigate cascading outages in high-voltage grids under multiple-fault conditions, where selected line switches or circuit breakers are opened in a controlled manner to isolate limited grid sections, minimize interrupted load, and prevent further overload propagation. The method combines inverse definite minimum time relay modeling with a heuristic graph-search algorithm implemented in pandapower to identify feasible switching actions that minimize load loss while preventing overload propagation. The approach is demonstrated on SimBench high-voltage urban and mixed benchmark grids under double-line fault scenarios. In the urban grid, the proposed scheme reduces the maximum load loss from 34.0% to 2.4%, while in the mixed grid, the reduction is from 50.3% to 5.2%. A SAIFI-inspired resilience proxy is introduced to quantify the reduction in customer/load interruptions, showing a resilience improvement factor of about 3.6 for cascading scenarios. In addition, thermal inertia analysis indicates that corrective switching must be completed within approximately 5 min to remain within line-temperature limits. The analysis is based on quasi-steady-state power-flow and relay simulations; transient stability effects are outside the scope of this study. The results demonstrate that the optimized overload tripping scheme is a promising adaptive protection strategy for improving grid resilience under severe contingency conditions.
Förderung
- German Federal Ministry of Education and Research
- University of Kassel
Zitieren
APA
Schmidt-Banerjee, G., Hachmann, C., & Braun, M. (2026). Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems. Energies, 19(10), 2468. https://doi.org/10.3390/en19102468
Vancouver
Schmidt-Banerjee G, Hachmann C, Braun M. Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems. Energies. 2026;19(10):2468. doi:10.3390/en19102468
BibTeX
@article{SchmidtBanerjee2026,
author = {Schmidt-Banerjee, Gourab and Hachmann, Christian and Braun, Martin},
title = {Resilience-Driven Overload Protection Framework for Mitigating Cascading Failures in Power Systems},
journal = {Energies},
year = {2026},
volume = {19},
number = {10},
pages = {2468},
doi = {10.3390/en19102468}
}