Transient Stability Analysis of DC Off-Grid Photovoltaic Hydrogen Production Systems Considering Electrolyzer Operating States
Energies · 22.04.2026 · 19 (9) · 2013
DOI: 10.3390/en19092013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 22.04.2026. Verfasst von Lingguo Kong und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jilin Province Science and Technology Department.
Abstract (Originalsprache)
This paper investigates the transient stability characteristics of a DC-coupled off-grid photovoltaic hydrogen production system. A nonlinear state-space model of the system is established by integrating the photovoltaic generation unit, the energy storage unit, and the electrolyzer unit. To enhance system dynamic performance, a virtual DC machine (VDCM) control strategy is introduced for the energy storage converter. Based on the nonlinear system model, a Takagi–Sugeno (TS) fuzzy model is constructed to approximate the system dynamics, and the largest estimated domain of attraction (LEDA) is derived using Lyapunov stability theory. Simulation studies are conducted to evaluate system stability under sudden photovoltaic power fluctuations caused by environmental disturbances, and the obtained LEDA is compared with the simulated attraction domain and the power boundary derived from the Lyapunov eigenvalue method. The results show that the LEDA obtained from the TS fuzzy model can effectively estimate the stability boundary of the system, although it remains slightly conservative. Furthermore, the impacts of VDCM control parameters and electrolyzer operating states on system stability are analyzed. Simulation results demonstrate that appropriate adjustment of system parameters can enlarge the LEDA and significantly improve the transient stability of the off-grid photovoltaic hydrogen production system.
Förderung
- Jilin Province Science and Technology Department
Zitieren
APA
Kong, L., Ding, Y., Tian, Y., & Xu, G. (2026). Transient Stability Analysis of DC Off-Grid Photovoltaic Hydrogen Production Systems Considering Electrolyzer Operating States. Energies, 19(9), 2013. https://doi.org/10.3390/en19092013
Vancouver
Kong L, Ding Y, Tian Y, Xu G. Transient Stability Analysis of DC Off-Grid Photovoltaic Hydrogen Production Systems Considering Electrolyzer Operating States. Energies. 2026;19(9):2013. doi:10.3390/en19092013
BibTeX
@article{Kong2026,
author = {Kong, Lingguo and Ding, Yuxuan and Tian, Yangjin and Xu, Guizhi},
title = {Transient Stability Analysis of DC Off-Grid Photovoltaic Hydrogen Production Systems Considering Electrolyzer Operating States},
journal = {Energies},
year = {2026},
volume = {19},
number = {9},
pages = {2013},
doi = {10.3390/en19092013}
}
EUVIMED