Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer

Huicui Chen, Weixuan Cheng, Ruirui Zhang, Pucheng Pei, Pingwen Ming

Energies · 03.04.2026 · 19 (7) · 1754

DOI: 10.3390/en19071754 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 03.04.2026. Verfasst von Huicui Chen und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gas bubble accumulation and transport play a critical role in the electrochemical performance and reaction uniformity of proton exchange membrane water electrolysis (PEMWE), particularly at high current density. However, the quantitative coupling between bubble coverage and local electrochemical activity remains insufficiently clarified. In this work, a visualization PEMWE combined with a printed circuit board (PCB)-based segmented measurement technique was developed to simultaneously characterize the spatial distributions of bubble coverage and local current density (LCD) under different current densities and operating temperatures. The results showed that both bubble coverage and LCD exhibited pronounced in-plane non-uniformity. The LCD generally displayed lower values in the central region and higher values near the edges, whereas high bubble coverage regions were mainly concentrated in the central and outlet-side areas. As the average current density increased from 0.5 A/cm2 to 2.0 A/cm2, the LCD range expanded from 0.43 to 0.53 A/cm2 to 1.75–2.20 A/cm2, while the local bubble coverage increased from 0.24 to 0.34 to 0.86–0.91. A clear negative spatial correlation between bubble coverage and LCD was identified, and this correlation became stronger with increasing current density. Moreover, the correlation exhibited marked spatial dependence, following the E5 > C3 > E1 > A5 > A1 order. Increasing the operating temperature from 50 to 70 °C alleviated the local heterogeneity, but it did not alter the fundamental coupling trend. These results demonstrate that bubble accumulation is a key factor governing current redistribution and local reaction non-uniformity in PEMWE, and they provide guidance for flow field optimization and high current density operation.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, H., Cheng, W., Zhang, R., Pei, P., & Ming, P. (2026). Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer. Energies, 19(7), 1754. https://doi.org/10.3390/en19071754

Vancouver

Chen H, Cheng W, Zhang R, Pei P, Ming P. Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer. Energies. 2026;19(7):1754. doi:10.3390/en19071754

BibTeX
@article{Chen2026,
  author = {Chen, Huicui and Cheng, Weixuan and Zhang, Ruirui and Pei, Pucheng and Ming, Pingwen},
  title = {Correlation Between Bubble Coverage and Current Density Distribution in a Proton Exchange Membrane Water Electrolyzer},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {7},
  pages = {1754},
  doi = {10.3390/en19071754}
}
Kostenlos starten →