EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Expanded Polystyrene for Building Insulation: Effect of Graphite and Moisture on Thermophysical Properties

Sereno Sacchet, Giovanni Paolo Lolato, Francesco Valentini, Maurizio Grigiante, Luca Fambri

Energies · 21.03.2026 · 19 (6) · 1558

DOI: 10.3390/en19061558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 21.03.2026. Verfasst von Sereno Sacchet und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union under NextGenerationEU.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Improving the energy efficiency of the building envelope is critical for global decarbonization, yet a gap remains in the comprehensive thermophysical characterization of carbon-enhanced Expanded Polystyrene (EPS). This study evaluates the impact of expansion ratios and moisture content on the thermal behavior of two commercial EPS grades, EPS-A (12.7 ± 0.5 kg/m3) and EPS-B (16.0 ± 1.1 kg/m3), investigating the counterintuitive role of graphite (1.4–1.8 wt.%) in enhancing the thermal insulation properties. Thermal conductivity and diffusivity were independently determined via Transient Plane Source (TPS) and Heat Flow Meter (HFM) methods across a 10–50 °C range, while specific heat capacity (cp) was analyzed using HFM and Differential Scanning Calorimetry (DSC) through the sapphire comparison method and Temperature-Modulated DSC (TOPEM®). Methodologically, it was found that standard HFM protocols are unsuitable for cp determination in low-density foams, yielding an average relative error of ±29%; conversely, the sapphire comparison method provided the most reliable results in agreement with theoretical expectations. Results indicate that the efficacy of graphite as a radiative shield is closely coupled with cellular morphology, proving significantly more effective in the higher expansion grade (EPS-A, 70 wt.% open porosity) than in the denser EPS-B. Furthermore, 30-day water immersion tests revealed that the higher open porosity of EPS-A facilitates increased water uptake of 144 ± 17 wt.% (compared to 97 ± 7 wt.% for EPS-B), causing the geometric densities of the two grades to converge and fundamentally altering thermal transport mechanisms. The study concludes that accurate thermal modeling of carbon-enhanced insulation requires careful selection of testing parameters, particularly when accounting for moisture-induced degradation in high-porosity systems.

Förderung

  • European Union under NextGenerationEU

Zitieren

APA

Sacchet, S., Lolato, G. P., Valentini, F., Grigiante, M., & Fambri, L. (2026). Expanded Polystyrene for Building Insulation: Effect of Graphite and Moisture on Thermophysical Properties. Energies, 19(6), 1558. https://doi.org/10.3390/en19061558

Vancouver

Sacchet S, Lolato GP, Valentini F, Grigiante M, Fambri L. Expanded Polystyrene for Building Insulation: Effect of Graphite and Moisture on Thermophysical Properties. Energies. 2026;19(6):1558. doi:10.3390/en19061558

BibTeX
@article{Sacchet2026,
  author = {Sacchet, Sereno and Lolato, Giovanni Paolo and Valentini, Francesco and Grigiante, Maurizio and Fambri, Luca},
  title = {Expanded Polystyrene for Building Insulation: Effect of Graphite and Moisture on Thermophysical Properties},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {1558},
  doi = {10.3390/en19061558}
}
Kostenlos starten →