EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sinusoidal Condenser Corrugations for Condition-Dependent Enhancement of Single-Loop Pulsating Heat Pipes

Wen Luo, Xinle Yang, Yongqing He

Energies · 16.03.2026 · 19 (6) · 1478

DOI: 10.3390/en19061478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 16.03.2026. Verfasst von Wen Luo und 2 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Liaoning Province, Scientific Research Project of Liaoning Provincial Education Department, School-Local Collaborative Technology Incubation Project of Liaoning Technical University Ordos Research Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulsating heat pipes (PHPs) are promising passive heat-transfer devices for compact thermal management; however, their performance is highly sensitive to channel geometry. In particular, the operating-condition-dependent influence of sinusoidal corrugation amplitude on the condenser side remains unclear, despite its importance for oscillation regulation and heat dissipation. This numerical study investigates a single-loop PHP with sinusoidally corrugated condensers (A = 0.25 and 0.5 mm) under heat fluxes of 5000–12,500 W/m2 and filling ratios of 40–60%, using a uniform-diameter PHP as the baseline. The results show that the configuration with A = 0.25 mm exhibits better start-up performance, especially at low heat fluxes, whereas both corrugated configurations provide better thermal performance than the baseline. At a filling ratio of 50%, the thermal-resistance reductions for A = 0.25 and A = 0.5 mm are 14.5% and 9.2% at 5000 W/m2 and 8.4% and 10.5% at 12,500 W/m2, respectively. An operating-condition-dependent amplitude-matching relationship is identified: The smaller amplitude is more favorable for start-up under weak driving conditions, whereas the larger amplitude tends to provide lower thermal resistance and higher equivalent thermal conductivity under strong driving conditions. These findings provide useful guidance for condenser-geometry optimization in single-loop PHPs.

Förderung

  • Natural Science Foundation of Liaoning Province
  • Scientific Research Project of Liaoning Provincial Education Department
  • School-Local Collaborative Technology Incubation Project of Liaoning Technical University Ordos Research Institute

Zitieren

APA

Luo, W., Yang, X., & He, Y. (2026). Sinusoidal Condenser Corrugations for Condition-Dependent Enhancement of Single-Loop Pulsating Heat Pipes. Energies, 19(6), 1478. https://doi.org/10.3390/en19061478

Vancouver

Luo W, Yang X, He Y. Sinusoidal Condenser Corrugations for Condition-Dependent Enhancement of Single-Loop Pulsating Heat Pipes. Energies. 2026;19(6):1478. doi:10.3390/en19061478

BibTeX
@article{Luo2026,
  author = {Luo, Wen and Yang, Xinle and He, Yongqing},
  title = {Sinusoidal Condenser Corrugations for Condition-Dependent Enhancement of Single-Loop Pulsating Heat Pipes},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {1478},
  doi = {10.3390/en19061478}
}
Kostenlos starten →