EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Heat Transfer and Thermal Efficiency Enhancement of Parabolic Trough Collectors Using Al2O3–Therminol VP-1 Nanofluids

Vijay Kumar Pandey, Om Prakash, Asim Ahmad, Sujit Kumar, Salem Algarni, Talal Alqahtani, Kashif Irshad, S M Mozammil Hasnain

Energies · 18.02.2026 · 19 (4) · 1051

DOI: 10.3390/en19041051 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 18.02.2026. Verfasst von Vijay Kumar Pandey und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Khalid University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A parabolic trough collector (PTC) is a linear concentrating system consisting of a parabolic-shaped reflector with a receiver tube positioned along the focal axis. In this study, the performance of a parabolic trough solar collector is evaluated, with aperture area, collector length, breadth, Rim angle, and inner and outer absorber diameters of 5.54 m2, 3.65 m, 1.52 m, 70°, 0.048 m, and 0.05 m, respectively. The experiment was conducted at Ranchi, India (23.35° N and 85.30° E). During this day, marked by a cloudless sky, the ambient temperature ranged from 27 °C to 39 °C. The global solar radiation ranged from (630 W/m2 to 975 W/m2), and the wind speed varied between (0.8 m/s and 1 m/s). Aluminium oxide (Al2O3) and Therminol VP-1-based nanofluid were employed as the working fluid. The different volume fractions of nanoparticles were taken, and the evacuated tube PTC performance was analysed. When Al2O3–Therminol VP-1 of varying concentration (0–4%) and mass flow rate of 0.041 kg/sec is used, it has been observed that the receiver’s heat transfer performance improved with an increment in nanoparticle volume fraction. Temperature-dependent properties were applied to the thermal efficiency, exhibiting a notable increase of approximately 7.2% when the volume fraction ascends from 0 to 4%. At elevated Reynolds numbers, the efficiency decreases compared to lower volume fractions. These results contribute to understanding the effect of nanoparticle concentration on PTC performance.

Förderung

  • King Khalid University

Zitieren

APA

Pandey, V. K., Prakash, O., Ahmad, A., Kumar, S., Algarni, S., Alqahtani, T., Irshad, K., & Hasnain, S. M. M. (2026). Heat Transfer and Thermal Efficiency Enhancement of Parabolic Trough Collectors Using Al2O3–Therminol VP-1 Nanofluids. Energies, 19(4), 1051. https://doi.org/10.3390/en19041051

Vancouver

Pandey VK, Prakash O, Ahmad A, Kumar S, Algarni S, Alqahtani T, et al. Heat Transfer and Thermal Efficiency Enhancement of Parabolic Trough Collectors Using Al2O3–Therminol VP-1 Nanofluids. Energies. 2026;19(4):1051. doi:10.3390/en19041051

BibTeX
@article{Pandey2026,
  author = {Pandey, Vijay Kumar and Prakash, Om and Ahmad, Asim and Kumar, Sujit and Algarni, Salem and Alqahtani, Talal and Irshad, Kashif and Hasnain, S M Mozammil},
  title = {Heat Transfer and Thermal Efficiency Enhancement of Parabolic Trough Collectors Using Al2O3–Therminol VP-1 Nanofluids},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {4},
  pages = {1051},
  doi = {10.3390/en19041051}
}
Kostenlos starten →