Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump
Energies · 30.01.2026 · 19 (3) · 733
DOI: 10.3390/en19030733 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 30.01.2026. Verfasst von Jeffrey Munk und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Energy Office of Critical Minerals and Energy Innovation Building Technologies Office.
Abstract (Originalsprache)
Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.
Förderung
- U.S. Department of Energy Office of Critical Minerals and Energy Innovation Building Technologies Office
Zitieren
APA
Munk, J., Marsik, T., Truffer-Moudra, D., Stevens, V., Dennehy, C., Winkler, J., & Strunk, R. (2026). Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump. Energies, 19(3), 733. https://doi.org/10.3390/en19030733
Vancouver
Munk J, Marsik T, Truffer-Moudra D, Stevens V, Dennehy C, Winkler J, et al. Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump. Energies. 2026;19(3):733. doi:10.3390/en19030733
BibTeX
@article{Munk2026,
author = {Munk, Jeffrey and Marsik, Tom and Truffer-Moudra, Dana and Stevens, Vanessa and Dennehy, Conor and Winkler, Jon and Strunk, Robby},
title = {Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump},
journal = {Energies},
year = {2026},
volume = {19},
number = {3},
pages = {733},
doi = {10.3390/en19030733}
}