An Adaptive Extended Kalman Filter with Passive Control for DC-DC Converter Supplying Constant Power and Constant Voltage Loads
Energies · 28.01.2026 · 19 (3) · 682
DOI: 10.3390/en19030682 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 28.01.2026. Verfasst von Peng Wang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: technology cooperation project of State Grid Heilongjiang Electric Power Co., Ltd..
Abstract (Originalsprache)
This article introduces an integrated control scheme combining an Adaptive Extended Kalman Filter (AEKF) with a Passivity-Based Control (PBC) approach to stabilize a DC-DC boost converter feeding both constant voltage and constant power loads (CPLs) in DC microgrids. Unlike conventional observers, the AEKF adapts its covariance matrices in real time to accurately estimate both system states and the unknown load dynamics introduced by CPLs, thereby eliminating the need for additional sensors and enhancing estimation convergence. Coupled with the PBC, the estimated disturbances are compensated via a feedforward path, significantly improving the system’s resilience to input voltage fluctuations and load variations. Through a Lyapunov-based stability analysis, the combined strategy is proven to ensure large-signal stability while maintaining a rapid transient recovery profile, even under significant parametric uncertainties. The simulation of this algorithm was implemented using PLECS, thoroughly validating the effectiveness and robustness of the proposed method.
Förderung
- technology cooperation project of State Grid Heilongjiang Electric Power Co., Ltd.
Zitieren
APA
Wang, P., Ma, Z., Tian, J., Li, Z., Li, Y., Wang, P., & Zhou, Y. (2026). An Adaptive Extended Kalman Filter with Passive Control for DC-DC Converter Supplying Constant Power and Constant Voltage Loads. Energies, 19(3), 682. https://doi.org/10.3390/en19030682
Vancouver
Wang P, Ma Z, Tian J, Li Z, Li Y, Wang P, et al. An Adaptive Extended Kalman Filter with Passive Control for DC-DC Converter Supplying Constant Power and Constant Voltage Loads. Energies. 2026;19(3):682. doi:10.3390/en19030682
BibTeX
@article{Wang2026,
author = {Wang, Peng and Ma, Zhenlong and Tian, Junfeng and Li, Zhe and Li, Yani and Wang, Panbao and Zhou, Yang},
title = {An Adaptive Extended Kalman Filter with Passive Control for DC-DC Converter Supplying Constant Power and Constant Voltage Loads},
journal = {Energies},
year = {2026},
volume = {19},
number = {3},
pages = {682},
doi = {10.3390/en19030682}
}