EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bees Algorithm and PSO-Optimized Hybrid Models for Accurate Power Transformer Fault Diagnosis: A Real-World Case Study

Mohammed Alenezi, Jabir Massoud, Tarek Ghomeed, Mokhtar Shouran

Energies · 13.11.2025 · 18 (22) · 5964

DOI: 10.3390/en18225964 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 13.11.2025. Verfasst von Mohammed Alenezi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cardiff University, School of Engineering.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduces an intelligent fault-diagnosis framework for power transformers that integrates hybrid machine-learning models with nature-inspired optimization. Current signals were acquired from a laboratory-scale three-phase transformer under both healthy and various fault conditions. A suite of 41 discriminative features was engineered from time–frequency and sparse representations generated via Discrete Wavelet Transform (DWT) and Matching Pursuit (MP). The resulting dataset of 2400 labeled segments was used to develop four hybrid models, PSO-SVM, PSO-RF, BA-SVM, and BA-RF, wherein Particle Swarm Optimization (PSO) and the Bees Algorithm (BA) served as wrapper optimizers for simultaneous feature selection and hyperparameter tuning. Rigorous evaluation with 5-fold and 10-fold cross-validation demonstrated the superior performance of Random Forest-based models, with the BA-RF hybrid achieving peak performance (98.33% accuracy, 99.09% precision). The results validate the proposed methodology, establishing that the fusion of wavelet- and MP-based feature extraction with metaheuristic optimization constitutes a robust and accurate paradigm for transformer fault diagnosis.

Förderung

  • Cardiff University, School of Engineering

Zitieren

APA

Alenezi, M., Massoud, J., Ghomeed, T., & Shouran, M. (2025). Bees Algorithm and PSO-Optimized Hybrid Models for Accurate Power Transformer Fault Diagnosis: A Real-World Case Study. Energies, 18(22), 5964. https://doi.org/10.3390/en18225964

Vancouver

Alenezi M, Massoud J, Ghomeed T, Shouran M. Bees Algorithm and PSO-Optimized Hybrid Models for Accurate Power Transformer Fault Diagnosis: A Real-World Case Study. Energies. 2025;18(22):5964. doi:10.3390/en18225964

BibTeX
@article{Alenezi2025,
  author = {Alenezi, Mohammed and Massoud, Jabir and Ghomeed, Tarek and Shouran, Mokhtar},
  title = {Bees Algorithm and PSO-Optimized Hybrid Models for Accurate Power Transformer Fault Diagnosis: A Real-World Case Study},
  journal = {Energies},
  year = {2025},
  volume = {18},
  number = {22},
  pages = {5964},
  doi = {10.3390/en18225964}
}
Kostenlos starten →